background image

Gait Up SA 

EPFL Innovation Park, Bat C. CH-1015 Lausanne 

www.gaitup.com 

TVA CHE-145.136.760 

 

 

User guide  PhysiRun Lab -  v1.1.1 Date: 06.05.2019 
Copyright © 2018-2019, All Rights Reserved - Gait Up SA. CH-1015 Switzerland   

 

 

 

  
 

 

User guide 

 

 

 
 
 
 
 

Summary of Contents for PhysiRun Lab

Page 1: ...EPFL Innovation Park Bat C CH 1015 Lausanne www gaitup com TVA CHE 145 136 760 User guide PhysiRun Lab v1 1 1 Date 06 05 2019 Copyright 2018 2019 All Rights Reserved Gait Up SA CH 1015 Switzerland 1...

Page 2: ...iRun Lab for running analysis The software allows to highlight a multitude of biomechanical parameters to observe the running technique with the GaitUp sensors Physilog 5 The Physilog 5 started from a...

Page 3: ...guration 4 2 3 Time setting 5 2 4 Fix the Sensors 5 2 5 Protocol 6 3 How to do a measurement with Physilog 5 6 3 1 Start measure from the watch 6 3 2 Start a measure from the Physilog 5 7 4 PhysiRun L...

Page 4: ...rement or by 3 rapid red blinks when you want to start a new measurement If the Physilog 5 is completely discharged charge at least 30 minutes before using Battery life estimation is available when yo...

Page 5: ...ctly set your files are saved in a folder with the measurement date If you start the sensors from the watch or the application the time is automatically updated and you thus don t need to follow the i...

Page 6: ...s BIN are saved in the sensor memory 8Go A file contains the raw data Below you can check the name description 3 1 Start measure from the watch A measurement from the watch allows to start and stop th...

Page 7: ...e started directly from the Physilog 5 Material required 2 Physilog 5 To start the measure hold the button for 3 seconds on each sensor Check that there is a green blinking on your two sensors after r...

Page 8: ...t on your computer Save your file in the same folder on your computer 1LF091 BIN for example If the time is correctly configured you file is saved in a folder at the date of measurement for example 18...

Page 9: ...different result files you want to obtain pdf excel file csv file In the PDF format there are three pages Excel and csv format give the cycle by cycle calculation for each parameter To generate these...

Page 10: ...llowing instructions carefully For sensors calibration move the gray window to have a part of static period and some running cycles see picture below To move the window click on the top bar You can al...

Page 11: ...s no space or special character allowed PDF excel and csv will have the same name The language for the PDF report can be selected from available translations in the list To obtain the third page of th...

Page 12: ...5 to measure water sport activities without additional waterproofing Storage Store in a cool 0 C 30 C and dry place The provided box is the perfect place for your sensor Cleaning Sensors can be cleane...

Page 13: ...log when the temperature is outside of the range of 0 to 45 C Physilog 5 should be charged through USB connection with a computer An external charger may be used note that no charger is provided by Ga...

Page 14: ...ks Error 2 3 rapid red blinks Error 3 4 rapid red blinks Error 4 5 rapid red blinks Error 5 6 rapid red blinks Error 6 Error type Error type How to solve the issue Error 1 Disconnect and replug the Ph...

Page 15: ...apply to any product or component thereof which has been repaired or altered by anyone other than Gait Up in any manner so as in Gait Up s judgement to affect its service ability or any product been s...

Page 16: ...ice may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operations a 5 When the device is so small or for such us...

Page 17: ...t us at EPFL Innov Park C CH 1015 Lausanne tel 41 21 633 7527 mail contact gaitup com web www gaitup com Document Version Changes Responsible Date 1 0 0 First public version Jules Gellaerts 29 11 18 1...

Reviews: