Remote control commands
R&S
®
NRPM
173
Mannual 1425.8663.02 ─ 08
...............................................................................................176
.............................................................................................177
........................................................................................177
........................................................................................178
...........................................................................................180
.......................................................................................... 180
TRIGger:BURSt:DELay
<delay>
List processing mode only
Sets the initial delay after the start burst until the first measurement starts.
Parameters:
<delay>
Range:
10e-6 to 1
*RST:
1e-3
Default unit: Seconds
Example:
TRIGger:BURSt:DELay 2e-3
TRIGger:ATRigger:DELay
<delay>
, this parameter determines after which
time an artificial trigger event is created, if no real trigger event has occurred.
Parameters:
<delay>
Range:
250e-6 to 5.0
*RST:
0.3
Default unit: s
TRIGger:ATRigger:EXECuted?
Queries the number of measurements which were triggered automatically, provi-
ded
is activated.
In scalar measurements, this number can only be 0 or 1. If you execute a buf-
fered measurement the number indicates how many results in the returned array
of measurement data were executed without a real trigger event.
Usage:
Query only
Configuring the trigger