Getting Started
R&S
®
SMC100A
45
Quick Start Guide 1411.4077.62 ─ 07
To indicate the active state, the "Modulation" block is displayed in blue. The "RF" is
not yet active, which means that no RF signal is output.
3. Set frequency and level and activate RF signal
a) Press the FREQ key to activate the editing mode for frequency entry. The "Fre-
quency" entry field in the header section of the display is highlighted.
Enter the frequency using the numeric keypad and terminate the entry by
pressing a unit key.
b) Press the LEVEL key and enter the level settings in the same way.
c) Press the DIAGRAM key to display the complete block diagram.
d) Turn the rotary knob to select the "RF" block.
Press the RF ON/OFF key to activate the "RF" block.
The AM modulation signal is now present at the RF output.
Generation of an RF Frequency Sweep Signal
In the example, an RF frequency sweep is configured. Proceed as follow:
1. Activate default (preset) state
Press the PRESET key to set a defined instrument state.
2. Configure and activate RF frequency sweep.
Example of Setup