Remote-control commands
DVB-H
54
Operating Manual 1008.0970.12 ─ 16
[:SOURce<hw>]:BB:DVB:SRATe:VARiation
<Variation>
The command enters the output sample rate.
A variation of this parameter only affects the ARB clock rate, all other signal parame-
ters remain unchanged. If the sampling rate in the frame configuration menu is
changed, this parameter is reset to the chosen sampling rate.
Parameters:
<Variation>
float
Range:
400 Hz to 40 MHz
*RST:
0.001 Hz
Example:
BB:DVB:SRAT:VAR 40 MHz
sets the output sample rate to 40 MHz.
Manual operation:
See
4.1.3 Clipping Settings
[:SOURce<hw>]:BB:DVB:CLIPping:LEVel
.......................................................................... 54
[:SOURce<hw>]:BB:DVB:CLIPping:MODE
......................................................................... 54
[:SOURce<hw>]:BB:DVB:CLIPping:STATe
.........................................................................55
[:SOURce<hw>]:BB:DVB:CLIPping:LEVel
<Level>
The command sets the limit for level clipping. This value indicates at what point the sig-
nal is clipped. It is specified as a percentage, relative to the highest level. 100% indi-
cates that clipping does not take place.
Parameters:
<Level>
integer
Range:
1 PCT to 100 PCT
Increment: 1 PCT
*RST:
100
Example:
BB:DVB:CLIP:LEV 80
sets the limit for level clipping to 80% of the maximum level.
BB:DVB:CLIP:STAT ON
activates level clipping.
Manual operation:
See
[:SOURce<hw>]:BB:DVB:CLIPping:MODE
<Mode>
The command sets the method for level clipping.