Installation Guide

rogerseller.com.au

Dimensions are approximate. Information provided in this installation guide is representative of the 
actual product available at the time of printing. Due to our policy of continuous product development, 
the design and specifications depicted are subject to change without notice. Please confirm all 
particulars with your sales consultant prior to purchase.

Viega More

13

14

15

16

18

19

20

17

STEP 03

13. Slide the Bowden wire unit 
onto the drain valve form the 
left-hand side until it snaps 
into place.

14. Replace the spacer into the 
cistern and attach onto the back 
wall of the cistern.

15. Turn the threaded bolts 
through 90˚ to secure them 
inside the drilled holes in the 
duct. The relevant depth of 
the threaded bolts should be 
taken from the instructions 
for use of the actuating panel.

16. Attach the Bowden wire 
unit to the rear of the base 
plate. Observe colour coding. 
Green Bowden wire should 
be attached to the place 
marked with a green dot.

17. Remove the push plate 
from the base plate.

More Series – Remove by hand.
Style Series – Use suction cups 
provided.

18. Attach the base plate and 
screw it into place with the 
screws supplied. 

19. Inset the push plate into 
the base plate.

20. Style Series – Please keep 
the suction caps provided, 
they will be needed for future 
maintenance.