10/25/2007
11
Restore power, the reader generates a continuous beep.
Wait until the LED SYSTEM (orange) starts flashing.
Disconnect DTA from IN1.
Present any card M times; where: M represents the first configuring digit D1.
Wait until the reader generates two beeps (
♪
♪
) as the prompt signal.
Present any card N times; where N represents the second configuring digit D2.
Wait until the reader generates two beeps (
♪
♪)
as the prompt signal.
Once the previous step has been completed the reader automatically ends the programming procedure
and enters the operating mode.
Example:
Configuring the PRT62 reader for ONLINE Wiegand 66 bit interface
Power down the unit.
Remove all connections from DTA and IN1 lines.
Connect DTA to IN1.
Restore power, the reader generates a continuous beep.
Wait until the LED SYSTEM (orange) starts flashing.
Disconnect DTA from IN1.
Present any card seven times to a reader.
Wait for the prompt signal (
♪
♪)
Present any card ten times to the reader.
Wait for the prompt signal (
♪
♪)
Once the previous step is completed the reader is configured for Wiegand 66 bit Operation Mode.
5.2
Memory Reset Procedure - Programming MASTER and INSTALLER cards
The
Memory Reset Procedure
erases from the PRT62 reader all MASTER and INSTALLER card information as
well as all programmed users (it clears all cards). Also, it causes the reader to restore factory default settings.
The
Memory Reset
execution is required only if the unit is configured for stand-alone mode
.
It does not affect
the unit that is configured for host-controlled (ONLINE) mode.
To clear the reader’s memory follow these steps:
Power down the unit.
Remove all connections from CLK and IN1 lines.
Connect CLK to IN1.
Restore power, the reader generates a continuous beep.
Wait until the LED OPEN (green) starts flashing.
Disconnect CLK from IN1.
Present any card to the reader — this card becomes a new MASTER Programming Card.
Present another (second) card to the reader — this card becomes a new INSTALLER Programming Card.
Once the previous step has been completed the reader automatically ends the Memory Reset Procedure
and enters ARMED mode.
5.2.1
Factory Default Settings
After Memory Reset the reader restores the following factory-shipped default set of settings:
Door lock triggering time: 4 sec.
Time allowed to close a door: 12 sec.
CLK or REL1 line function:
Door Lock Output
.
DTA or REL2 line function
: Reader Disarmed Output
.
Line IN1 on the reader:
Door Contact Input
.
Line IN1 on the XM-2 module:
Exit Button Input
.
Line IN2 on the XM-2 module:
Ready Input
.
Option
Door Alarm Indication On Internal Buzzer
: Option disabled.
Option
Access Disabled When Reader Armed
: Option disabled.
Summary of Contents for PRT62
Page 1: ...Installation and Programming Guide PRT62 v1 1 Outdoor Access Control Terminal Firmware v74 7 ...
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ... This page intentionally left blank ...
Page 28: ......