PR311-BK fv102 Rev B. ENG.doc.DOC
8/9/2006
_________________________________________________________________________________________
_________________________________________________________________________________________
Page
11
•
by the input line configured to function no. 78:
Disarmed mode momentary
switch
•
by the input line configured to function no. 79:
Armed mode momentary
switch
•
by the MASTER user (by using of the MASTER identifier)
•
by the TOGLLE user (by using of the TOGGLE identifier)
•
by the TOGGLE LTD user (by using of the TOGGLE LTD identifier)
•
by an interactive command from PC
•
by the
Armed/Disarmed Schedule
Note: Except first mentioned method, all other methods can be used
simultaneously to
Arm/Disarm
the controller – as a result the controller will employ
the arming condition which was indicated by the last event (command). When
arming mode of a controller is controlled by input:
Arming/Disarming steady
switch,
all other methods of rearming are inoperative.
Reader rearming command can be issued by MASTER, TOGGLE or TOGGLE LTD
users. To rearm the reader a MASTER and TOGGLE (with or without
AWA Privilege
)
users are required to enter their identifier twice, whereas a TOGGLE LTD user must
enter his identifier once only.
Note: The manual rearming of the controller through TOGGLE or MASTER users can
be carried out either from the controller PR311-BK or from the external reader.
Example1
. Rearming of the controller by using a TOGGLE identifier (when the
Card
Only
mode is active).
•
Read your TOGGLE card, with the first use of the card controller will release a
lock and start flashing LED SYSTEM
•
When the LED SYSTEM is flashing, read your TOGGLE user card once again
•
after the last step controller will changed its arming mode (watch for the LED
STATUS which will changed their color)
4.7.
Unlocking the Door
In order to unlock the door user is required to use his identifier once. Whenever
this happens the reader activates LED SYSTEM (orange) for a moment and
generates a short confirmation beep. After successful identification reader unlocks
the door for the predefined time specified by:
Door unlock time
. The lock
activation is indicated on LED OPEN (green), which remains ON for as long as the
door lock is released. When the option:
Auto-relock
, is active the door lock is
released till the moment when door become open.
Note: The LED OPEN is activated for the entire time when door lock is released.
When access to the supervised room is denied the reader may generate either the
one long beep or two short beeps. The one long acoustic signal indicates that
presented identifier is not registered in the controller (identifier is unknown)