Door contact
1
Input is dedicated for a contact used to indicate that the
corresponding door is open.
Exit button -
momentary switch
2
Input is dedicated for the operation with a button which will be used
to open the corresponding door without using any identifier.
Activation of this input will activate the door lock for the same time
period as defined by
Door unlock time
. This function is usually
used to enable connection of a
Request To Exit
(REX) button.
Arm/Disarm steady
switch
3
When input is triggered controller switches unconditionally to
Disarmed
mode.
Note:
Only one input on the controller can be configured to this
function. When this function is selected any other methods of
Arming/Disarming
are disabled.
AUX
4
Whenever this input goes on or off the adequate event is registered
in history (when controller operates in
Integrated Access Control
System
)– no other effects.
AC lost
5
Input is dedicated for connection to an output line or a contact which
is used to indicate a loss of AC power supply. Each time this input is
triggered it sets the TROUBLE flag on.
Low battery
6
Input is dedicated for connection to an output line or a contact which
is used to indicate the low level of reserve battery. Each time this
input is triggered it sets the TROUBLE flag on.
Bell button
7
Each time this input is triggered controller activates the
Door bell
output (function no. 15). Input is dedicated for connection to a
button used to indicate that somebody wants to enter the premises.
Tamper
8
Tamper loop input. Each time this input is triggered it activates the
TAMPER flag timer which can further activate (if programmed) the
Tamper
output (Function no. 65).
Access disabled
11
When triggered disables access to a room or area.
Arming disabled
13
When input is triggered controller can’t be armed.
Note: This input does not affect arming when it is carried out by
input
Disarm steady switch
(function no. 3).
Exit button steady
switch
14
Triggering of this input unlocks the door. Door remains unlocked as
long as input is triggered.
Arm/Disarm
momentary switch
61
Each time this input is triggered the controller reverses its arming
condition (goes from Armed to Disarmed or vice versa).
Normal door mode
64
Triggering of this input sets
Normal
door mode.
Unlocked door mode
65
Triggering of this input sets
Unlocked
door mode.
Conditional Unlocked
door mode
66
Triggering of this input sets
Conditional Unlocked
door mode.
Locked door mode
67
Triggering of this input sets
Locked
door mode.
LIGHT flag on
68
Triggering of this input sets LIGHT flag on.