PR311-BK fv102 Rev B. ENG.doc.DOC
8/9/2006
_________________________________________________________________________________________
_________________________________________________________________________________________
Page
18
LIGHT flag off
69
Triggering of this input sets LIGHT flag off.
Toggle LIGHT flag
on/off
70
Triggering of this input toggles LIGHT flag on/off.
AUX1 flag on
71
Triggering of this input sets AUX1 flag on.
Set AUX1 flag off
72
Triggering of this input sets AUX1 flag off.
Toggle AUX1 flag
on/off
73
Triggering of this input toggles AUX1 flag on/off.
Disarmed mode
78
Triggering of this input switches controller to
Disarmed
mode.
Armed mode
79
Triggering of this input switches controller to
Armed
mode.
Card or PIN mode
80
Triggering of this input sets
Card or PIN
identification mode for
terminal ID1.
Card only mode
81
Triggering of this input sets
Card only
identification mode for
terminal ID1.
PIN only mode
82
Triggering of this input sets
PIN only
identification mode for terminal
ID1.
Card and PIN mode
83
Triggering of this input sets
Card and PIN
identification mode for
terminal ID1.
Note:
It is not allowed to program two or more inputs to the same function.
4.19.
Outputs
The PR311-BK provides five logical outputs. Three of them (called OUT1, OUT2 and
OUT3) are located on the controller’s electronic module while two others (OUT4,
OUT5) are located on the optional XM-2 extension module. The OUT1 is a relay
output with one NO/NC/COM contact. The OUT2 and OUT3 are transistor types
capable to sink up to 1A DC current. Regardless of the output type and its location
(internal on the controller or external on the extension module) they can be
configured to one from the following list of functions:
Table 5. Output lines functions.
Function
Number
Description
Disarmed mode
0
Whenever controller switches to
Disarmed
mode this output goes on
and remains on as far as controller is disarmed.
Prealarm
1
Door Ajar
2
Pr
Door Ajar
3
Forced Entry
4
Pr
Forced Entry
5
The output is dedicated to indicate one or more alarm situation which
occurred on the controller. Depending on programmed function (01-07)
the output can signal one or more type of alarms. If more then one
alarm exists, the output signals alarm with highest priority. Each alarm
is signaled through different modulation of an output line.