background image

HRT82TS Installation Guide Rev.C.doc

 

2016-10-10 

 

 

4/9 

 

3.3 RACS CLK/DTA communication bus 

RACS CLK/DTA is the addressable bidirectional communication standard developed and applied in 
Roger controllers in order to enable their communication with peripheral devices. Addresses of all 

devices connected to CLK and DTA lines must be properly configured in range of 00..15. Standard 
unshielded  signal  cables (e.g. U/UTP cat. 5)  with maximal length of 150m can be used  for RACS 

CLK/DTA communication. 

3.4 Front panel 

HRT82TS is equipped with front icon backlight which is used for signalling proper operation (steady 
light) or communication problems (blinking). 

3.5 Wall mounting and installation guidelines 

HRT82TS  consists  of  front  panel  and  base  which  are  factory  assembled  and  require  manual 
disassembly prior to installation according to fig. 4. 

Installation guidelines 

 

Install device on wall far from sources of heat and moisture 

 

It is recommended to install device on Ø60mm flush mounting box 

 

Front  panel  and  base  must  be  properly  oriented  in  order  to  ensure  functioning  of  tamper 
resistance. 

 

All electric connections must be made with power supply switched off 

 

Run connection wires through hole in device base and then connect wires to screw terminals 

 

If  device  and  controller  are  supplied  from  different  power  supply  units  then  it  is  necessary 
connect GND terminals of both devices 

 

Front panel can be regularly cleaned with wet cloth and mild detergent. Do not clean by means 
of abrasive materials and strong cleaners like alcohols, solvents, etc. 

 

Damages resulting from improper maintenance or use are not covered by warranty 

 

Summary of Contents for HRT82TS

Page 1: ...re version 1 0 8 23 or newer Hardware version 1 0 Document version Rev C 2016 ROGER sp z o o sp k All rights reserved This document is subject to the Terms of Use in their current version published at the www roger pl website of the Roger sp z o o sp k company hereinafter referred to as ROGER ...

Page 2: ...bles room temperature readout allowing the controller to control air conditioning and or heating systems Interchangeably room temperature can also be read by means of such devices with built in temperature sensors as HRT82AC air conditioning control panel and HRT82MF CH card holder Table 1 Specification Supply voltage Nominal 12VDC min max range 10 15VDC Average current consumption 25mA Tamper res...

Page 3: ...nominal power supply The power must be connected to 12V and GND terminals Additionally the GND terminal is used as reference potential for the RACS CLK DTA bus HRT82TS power supply can be provided by connection to buffer power supply unit e g PS 15DR PS20 or connection to AUX output of HRC402DR controller see fig 2 Backup battery connected to power supply unit or directly to HRC402DR controller ca...

Page 4: ... of front panel and base which are factory assembled and require manual disassembly prior to installation according to fig 4 Installation guidelines Install device on wall far from sources of heat and moisture It is recommended to install device on Ø60mm flush mounting box Front panel and base must be properly oriented in order to ensure functioning of tamper resistance All electric connections mu...

Page 5: ...HRT82TS Installation Guide Rev C doc 2016 10 10 5 9 Fig 4 HRT82TS latches and wall mounting ...

Page 6: ...on interface according to fig 5 2 Place jumper on MEM pins 3 Restart the device place and remove jumper on RST pins or switch power supply off and on 4 Install and start RogerVDM software 5 In the opened window select device firmware version communication channel and serial port with connected RUD 1 see fig 6 6 Select Connect button the software shall establish connection with the device and autom...

Page 7: ...en failure is not signalled at all 4 2 Firmware update HRT82TS firmware can be updated with RogerVDM available at www roger pl after connection to RUD 1 communication interface Firmware update procedure 1 Connect device to RUD 1 communication interface according to fig 5 2 Install and start RogerVDM software 3 Close Select Device window 4 In top menu select Tools Update firmware 5 In the opened wi...

Page 8: ...see 4 1 5 TROUBLESHOOTING Table 4 Troubleshooting Issue Visual indication Acoustic indication Solution No communication with controller Front panel icon backlight blinking 1 Check if RACS CLK DTA bus is properly connected wires are undamaged and the bus does not exceed 150 m All devices connected to particular RACS CLK DTA bus should have common supply minus GND 2 Check if the controller is proper...

Page 9: ...is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information on recycling contact your local authorities waste disposal company or point of purchase Separate collection and recycling of this type of waste contributes to the protection of the natural resources and is safe to health and the environment Weight of the equipment is specif...

Reviews: