background image

HRT82MF-CH Installation Guide.doc

 

2018-09-21 

 

 

9/11 

 

CSN Number of 
Bytes 

0..8 

The parameter specifies how many bytes of read only Chip 
Serial Number (CSN) is used in UID card number. 

Mifare Classic Settings 

Card number 

CSN, MSN. 
SSN 

When CNS is selected then UID includes only this number. 
When MSN or SSN is selected then it is possible to use 

administrator defined UID. It is also possible to define UID 
consisting partially of CSN and MSN or SSN.  

Format 

BIN, HEX 

ASCII 

Card number format. When BIN is selected then bytes from 

card correspond to UID number. When HEX ASCII is 
selected then bytes from card correspond to UID in ASCII 

hexadecimal format.  

LSB 

0..15 

The location of MSN or SSN first byte. 

MSB 

0..15 

The location of MSN or SSN last byte. 

Sector ID 

0..39 

Sector number with SSN. For MSN this setting is disabled. 

AID 

0000..FFFF 

AID number in MAD sector which defines sector with MSN. 
For SSN this setting is disabled. 

Block ID 

0..14 

Block number in the sector with MSN or SSN. 

Key Type 

A, B , Roger 

Type of key used for reading MSN or SSN. 

Key 

00000000000..
FFFFFFFFFFFF 

Six bytes key used for reading MSN or SSN. 

4.2 Firmware update 

HRT82MF-CH  firmware  can  be  updated  with  RogerVDM  (available  at 

www.roger.pl

)  after 

connection to RUD-1 communication interface. 

Firmware update procedure 

1.

 

Connect device to RUD-1 communication interface according to fig. 6 

2.

 

Install and start RogerVDM software 

3.

 

Close 

Select Device

 window 

4.

 

In top menu select 

Tools->Update firmware

 

5.

 

In the opened window select device, port with connected RUD-1 and specify path to firmware 

file (*.hex) – see fig. 9 

6.

 

According  to displayed  message place jumper  on FDM pins and  restart the device (place and 

remove jumper on RST pins or switch power supply off and on) 

7.

 

Select 

Update

 button 

8.

 

After  firmware  upload  remove  jumper  from  FDM  pins  and  reset  device  (place  and  remove 

jumper on RST pins or switch power supply off and on) 

 

Summary of Contents for HRT82MF-CH

Page 1: ...ion 1 0 2 16 or newer Hardware version 1 0 Document version Rev D 2016 ROGER sp z o o sp k All rights reserved This document is subject to the Terms of Use in their current version published at the ww...

Page 2: ...CSN reading for such cards as MIFARE Ultralight Classic Plus Desfire Additionally it allows to read configurable Mad Sector Number MAD and Sector Serial Number SSN as well as combinations of CNS and...

Page 3: ...ion diagram Fig 1 HRT82MF CH card holder Table 2 HRT82MF CH terminals Term Description Term Description 12V 12VDC power supply CLK RACS CLK DTA bus GND Ground DTA RACS CLK DTA bus IN1 not used TMP Tam...

Page 4: ...shielded signal cables e g U UTP cat 5 with maximal length of 150m can be used for RACS CLK DTA communication 3 4 Front panel HRT82MF CH front panel includes card holder At the holder entry white back...

Page 5: ...HRT82MF CH Installation Guide doc 2018 09 21 5 11 Damages resulting from improper maintenance or use are not covered by warranty Fig 4 HRT82MF CH latches and surface mounting...

Page 6: ...HRT82MF CH Installation Guide doc 2018 09 21 6 11 Fig 5 HRT82MF CH F flush mounting...

Page 7: ...place and remove jumper on RST pins or switch power supply off and on 4 Install and start RogerVDM software 5 In the opened window select device firmware version communication channel and serial port...

Page 8: ...d with any comment by installer Transmission Format RACS CLK DTA Address 0 15 Device address on RACS CLK DTA bus Default address ID 0 is required for communication with HRC controller Communication ti...