background image

HRT82MF-CH Installation Guide.doc

 

2018-09-21 

 

 

2/11 

 

1.

 

I

NTRODUCTION

 

This  manual  contains  minimum  information  that  is  necessary  to  properly  install  device.  Following 
documents supplement this manual: 

 

Functional description of HRC series controllers 

 

Installation guide for HRC series controllers 

In  order  to  acquire  the  first  one  it  is  necessary  to  obtain  Roger  consent  and  sign  non-disclosure 
agreement (NDA). The second one is available at 

www.roger.pl

. 

2.

 

D

ESCRIPTION AND SPECIFICATION

 

HRT82MF-CH  card  holder  is  peripheral  device  used  in  a  hotel  system  based  on  HRC  series 
controllers.  The  device  communicates  with  controller  using  RACS  CLK/DTA  bus  and  periodically 

reads card in its holder in order to enable monitoring of card owner presence (i.e. guest or hotel 
staff)  in  hotel  room.  Such  monitoring  can  be  used  for  230VAC  power  supply  switching,  air 
conditioning and/or hotel automation control. The device enables serial number (CSN) reading for 
such  cards  as  MIFARE®  Ultralight/Classic/Plus/Desfire.  Additionally  it  allows  to  read  configurable 
Mad  Sector  Number  (MAD)  and  Sector  Serial  Number  (SSN)  as  well  as  combinations  of  CNS  and 

MSN or SSN for MIFARE Classic cards.  
HRT82MF-CH  front  panel  includes  card  holder.  The  device  is  equipped  with  front  panel  backlight 

and  buzzer.  The  device  is  offered  in  two  versions:  HRT82MF-CH  for  surface  mounting  and 
HRT82MF-CH-F for flush mounting. 
 

Table 1. Specification 

Supply voltage 

Nominal 12VDC, min./max. range 10-15VDC 

Proximity cards 

13.56MHz in acc. with ISO14443A and MIFARE 

Reading distance 

Up to 15 cm for ISO cards (depends on card type and quality) 

Average current 
consumption  

60mA 

Tamper resistance 

Isolated contact, NC type (normally closed when enclosure is assembled 

and attached), 24V/50mA 

Distance 

Between controller and HRT device (RACS CLK/DTA): max. 150m 

Environmental class 

(acc. to EN 50131-1) 

Class II, indoor general conditions, temperature: -10°C- +50°C, relative 

humidity: 10 to 95% (no condensation) 

IP code 

IP41 

Dimensions HxWxD 

HRT82MF-CH:   

85 x 85 x 27 mm 

HRT82MF-CH-F:   

105 x 105 x 31 mm 

Weight 

~ 100g 

Certificates 

CE 

 

Summary of Contents for HRT82MF-CH

Page 1: ...ion 1 0 2 16 or newer Hardware version 1 0 Document version Rev D 2016 ROGER sp z o o sp k All rights reserved This document is subject to the Terms of Use in their current version published at the ww...

Page 2: ...CSN reading for such cards as MIFARE Ultralight Classic Plus Desfire Additionally it allows to read configurable Mad Sector Number MAD and Sector Serial Number SSN as well as combinations of CNS and...

Page 3: ...ion diagram Fig 1 HRT82MF CH card holder Table 2 HRT82MF CH terminals Term Description Term Description 12V 12VDC power supply CLK RACS CLK DTA bus GND Ground DTA RACS CLK DTA bus IN1 not used TMP Tam...

Page 4: ...shielded signal cables e g U UTP cat 5 with maximal length of 150m can be used for RACS CLK DTA communication 3 4 Front panel HRT82MF CH front panel includes card holder At the holder entry white back...

Page 5: ...HRT82MF CH Installation Guide doc 2018 09 21 5 11 Damages resulting from improper maintenance or use are not covered by warranty Fig 4 HRT82MF CH latches and surface mounting...

Page 6: ...HRT82MF CH Installation Guide doc 2018 09 21 6 11 Fig 5 HRT82MF CH F flush mounting...

Page 7: ...place and remove jumper on RST pins or switch power supply off and on 4 Install and start RogerVDM software 5 In the opened window select device firmware version communication channel and serial port...

Page 8: ...d with any comment by installer Transmission Format RACS CLK DTA Address 0 15 Device address on RACS CLK DTA bus Default address ID 0 is required for communication with HRC controller Communication ti...

Page 9: ...D sector which defines sector with MSN For SSN this setting is disabled Block ID 0 14 Block number in the sector with MSN or SSN Key Type A B Roger Type of key used for reading MSN or SSN Key 00000000...

Page 10: ...stic indication Solution No communication with controller Green red backlight is blinking 1 Check if RACS CLK DTA bus is properly connected wires are undamaged and the bus does not exceed 150 m All de...

Page 11: ...as this may have a negative impact on the environment and health The user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information...

Reviews: