HRT82MF-CH Installation Guide.doc

 

2018-09-21 

 

 

11/11 

 

6.

 

O

RDERING INFORMATION

 

Table 5. Ordering information 

HRT82MF-CH  MIFARE hotel card holder 

RUD-1 

Communication interface with 12VDC power supply output 

 

7.

 

P

RODUCT HISTORY

 

Table 6. Product history 

Version 

Released 

Description 

HRT82MF-CH v.1.0  07/2014 

The first commercial version of the product 

 
 

 
 
 

 
 

 
 
 

 
 

 
 

 

 

This symbol placed on a product or packaging indicates that the 
product should not be disposed of with other wastes as this may 

have a negative impact on the environment and health. The user 
is obliged to deliver equipment to the designated collection points 

of electric and electronic waste. For detailed information on 
recycling, contact your local authorities, waste disposal company 
or point of purchase. Separate collection and recycling of this type 

of waste contributes to the protection of the natural resources 
and is safe to health and the environment. Weight of the 

equipment is specified in the document. 

 
 
 

Contact: 

Roger sp. z o.o. sp.k. 

82-400 Sztum 

Gościszewo 59 

Tel.: +48 55 272 0132 
Fax: +48 55 272 0133 

Tech. support: +48 55 267 0126 

E-mail: 

[email protected]

 

Web

www.roger.pl

 

Summary of Contents for HRT82MF-CH

Page 1: ...ion 1 0 2 16 or newer Hardware version 1 0 Document version Rev D 2016 ROGER sp z o o sp k All rights reserved This document is subject to the Terms of Use in their current version published at the ww...

Page 2: ...CSN reading for such cards as MIFARE Ultralight Classic Plus Desfire Additionally it allows to read configurable Mad Sector Number MAD and Sector Serial Number SSN as well as combinations of CNS and...

Page 3: ...ion diagram Fig 1 HRT82MF CH card holder Table 2 HRT82MF CH terminals Term Description Term Description 12V 12VDC power supply CLK RACS CLK DTA bus GND Ground DTA RACS CLK DTA bus IN1 not used TMP Tam...

Page 4: ...shielded signal cables e g U UTP cat 5 with maximal length of 150m can be used for RACS CLK DTA communication 3 4 Front panel HRT82MF CH front panel includes card holder At the holder entry white back...

Page 5: ...HRT82MF CH Installation Guide doc 2018 09 21 5 11 Damages resulting from improper maintenance or use are not covered by warranty Fig 4 HRT82MF CH latches and surface mounting...

Page 6: ...HRT82MF CH Installation Guide doc 2018 09 21 6 11 Fig 5 HRT82MF CH F flush mounting...

Page 7: ...place and remove jumper on RST pins or switch power supply off and on 4 Install and start RogerVDM software 5 In the opened window select device firmware version communication channel and serial port...

Page 8: ...d with any comment by installer Transmission Format RACS CLK DTA Address 0 15 Device address on RACS CLK DTA bus Default address ID 0 is required for communication with HRC controller Communication ti...

Page 9: ...D sector which defines sector with MSN For SSN this setting is disabled Block ID 0 14 Block number in the sector with MSN or SSN Key Type A B Roger Type of key used for reading MSN or SSN Key 00000000...

Page 10: ...stic indication Solution No communication with controller Green red backlight is blinking 1 Check if RACS CLK DTA bus is properly connected wires are undamaged and the bus does not exceed 150 m All de...

Page 11: ...as this may have a negative impact on the environment and health The user is obliged to deliver equipment to the designated collection points of electric and electronic waste For detailed information...

Reviews: