8
EN
CONTENTS Page
2
Product description
The numeric code keypad allows for the activation
of the radio transmission only after having entered
an enabled code, i.e. one previously stored in the
memory of the keyboard: this makes the activation
of the device more secure, as well as the activation/
de-activation of the alarms. The keyboard is
configured as per the production standard to
work with fixed code ROGER radio receivers
(H93/
RX22A/I,
R93/RX12A/I
and
R93/RX12A/U).
It is
possible to change the type of transmission, in
order to, as an alternative, attain compatibility with
"rolling code" receivers
H93/RX2RC/I
and
R93/
RX2RC/U
which adopt the RTHSE standard (Roger
Technology High Security Encryption). The "rolling
code" transmission is recommended for installations
requiring a very high level of security, thanks to the
144-bit processed through multi-level encryption.
It is possible to store up to 450 user codes, each
of which can have a maximum of 6 digits. To store
codes you need to know the password, which must
be customized during installation in order to ensure
the security of access. By making the password
change, the transmission mode is also started (fixed
or "rolling" code).
When choosing user codes it is recommended to
use up to 5 digits for optimal system security as
well as ease of use; for the more demanding users
who seek maximum security there is a special
mode, which is described in section 6 ADVANCED
FEATURES: MASKING OF THE CODE.
The wireless numeric code keypad exists in three
versions:
• H85/TDR/E
: version for wall mounting
• H85/TDR/C
: version for mounting on pedestal
• H85/TDR/I
: built-in version
Spare part code:
• H85/TDR
: replacement wireless keyboard,
includes all the components shown in
Figure 1
.
1
Introduction to the instructions and
warnings
This manual is only intended for qualified technical
installation personnel.
None of the information contained in this
document may be considered of interest to the
end user.
This manual refers to the wireless numeric code
keypads of the ROGER series H85/TDR for ROGER
automation control and other devices that are
within the specifications.
Read the instructions carefully before installation.
In accordance with the relevant legislation,
installation should only be performed by qualified
service personnel.
Make the connections with the cables that are
suitable for the specified currents and voltages,
respect the technical specifications of the product.
CAUTION! These devices are sensitive to
electrostatic discharges, therefore avoid touching
the sides of the card and wires with your hands.
WARNINGS
1 Introduction to the instructions and warnings 8
2 Product description
8
3 Technical specifications
9
4 Functioning of the keys and messages
9
5 Installation
9
5.1 Changing the password
10
5.2 Completely deleting user codes
10
5.3 Storing a user code
10
5.4 Storing on the radio receiver
11
5.5 Activation of the radio transmission
11
5.6 Deleting a user code
11
6 Advanced Features: masking the code
11
7 Error message
12
8 Keypad lock message
12
9 Low battery indicator
12
10 Replacing the batteries
12
11 Testing
12
12 Maintenance
13
13 Disposal
13
14 Pictures and schemes
38