CONNECTIONS TABLE
AP – COM
normally open contact
OPEN INPUT BUTTON
CH – COM
normally open contact
CLOSE INPUT BUTTON
PED – COM
normally open contact
PEDESTRIAN OPENING INPUT BUTTON
ORO – COM normally open contact
CLOCK INPUT
ANT
COM
central pole of the cable
shield
ANTENNA
We recommend the use of RG58 coaxial cable (50Ω)
PP – COM
normally open contact
STEP BY STEP BUTTON
ST – COM
normally close contact
STOP BUTTON
COS1 – COM normally close contact
SAFETY EDGE 1 CONNECTION (OPENING)
COS2 – COM normally close contact
SAFETY EDGE 2 CONNECTION (CLOSING)
FT1 – COM
normally close contact
PHOTOCELL 1 CONNECTION
FT2 – COM
normally close contact
PHOTOCELL 2 CONNECTION
SC – COM
24Vcc MAX. 2W
OPEN GATE LIGHT CONNECTION
slow flashing in opening, fast flashing in closing and fixed when
the gate is open, double flashing with gate stopped in the
middle of the travel
24V
COM
+24Vcc MAX.300mA
0V MASSA
POWER ACCESSORIES (e.g. photocells)
AP-COM-CH 230Vac 50Hz
MOTOR POWER
MOTOR CAPACITOR
COR
Tension free contact 5A
COURTESY LIGHT CONNECTION
LAM
Tension free contact 1A
FLASHING LIGHT CONNECTION
F-N-
230Vac 50Hz
CONTROL UNIT POWER
THE CONTROL UNIT SHOULD NOT BE SUPPLIED WITH
GENERATOR THAT DOES NOT WARRANT THE 50Hz
FREQUENCY WITH A NETWORK-COMPARABLE ACCURACY
PHOTOCELLS CONNECTIONS