![Rofin PowerLine E Air 10 Maintenance And Integration Manual Download Page 28](http://html1.mh-extra.com/html/rofin/powerline-e-air-10/powerline-e-air-10_maintenance-and-integration-manual_1476994028.webp)
Maintenance
18
PowerLine E Air
2.1
Changing the filter mat/s
The components in the 19" plug-in for electrical components are cooled by a separated routing of
air flow.
Depending on the laser, the 19" plug-in for electrical components has one or two filter mats,
respectively, to protect it from soiling.
PowerLine E Air 10
PowerLine E Air 25/ 30
Attention
1
–
Change the filter mat/s at least once a year, or more regularly depending on the level of
soiling.
–
Make sure that the filter mats remain sufficiently pervious to ensure the required heat
exchange.
–
Dispose of used filter mats as commercial waste.
–
Exclusively use the filter mats listed in the "Spare Parts" chapter (see Section "3, Spare parts"
on page 25).
–
Never operate the system without filter mats. Non-compliance may affect the cooling
performance and cause damage to the components inside the 19" plug-in for electrical
components.
Attention
1
Switch the laser system off properly.
A white filter mat is located in the front behind the
grille in the 19" plug-in for electrical components.
FIG. 22 Filter mat in the 19" plug-in for electrical
components
One white and one black filter mat is located in
the front behind the grille in the 19” plug-in for
electrical components.
1
Attention
Make sure to correctly position the black and
white filter mats in the front behind the grille in the
19" plug-in for electrical components
.
FIG. 23 Filter mats in the 19" plug-in for electrical
components
white filter mat
black filter mat on the left side /
white filter mat on the right side
Summary of Contents for PowerLine E Air 10
Page 1: ...THE MARK OF EXCELLENCE PowerLine E Air Maintenance and Integration Manual Version 1 3 7...
Page 2: ......
Page 8: ...viii...
Page 26: ...Safety 16 PowerLine E Air...
Page 40: ...Spare parts 30 PowerLine E Air...
Page 74: ...Integrating the laser system 64 PowerLine E Air FIG 50 19 plug in PC 2HE...