- zone 3 - Instant with continuous alarm
- zone 4 - 24-hour with pulsing alarm
After entering the section by pressing [0][1], enter the sequence:
[0] [0] [2] [0] [1] [0] [3] [1]
After every 2 digits, the keypad buzzer will sound 3 beeps. After the last 2
digits, the keypad buzzer will sound 6 beeps and will exit section [01],
waiting for a new command.
S
ECTION
[02] - KEY Z
ONE
D
EFINITION
Enter 2 digits to determine KEY zone characteristics.
First digit represents KEY zone type and could be:
[3] P
ANIC
OR
T
AMPER
The Panic zone is permanently active and it will generate alarm even if the
system is disarmed.
[4] K
EY
A
RMING
/ D
ISARMING
The system could be armed/disarmed using a Normally Closed keyswitch.
The keyswitch used should be a kind of a momentary keyswitch. If the
system is disarmed, then zone opening will arm the system. If the system is
armed, then zone opening will disarm the system. If the siren is activated,
then zone opening will stop the siren.
The second digit indicates the alarm type produced by the KEY zone.
The same kind of alarm will produce the simultaneous pressing of [*]
and [#] keys. The programming is the same as in section [01].
S
ECTION
[03] - S
YSTEM
T
IMES
Enter 3 groups of 3 digits each, to establish respectively the three system
times:
E
NTRY
D
ELAY
(001 to 255 seconds). The Entry Delay determines the amount of time
permitted between the activation of an Entry/Exit zone and the disarming of
the system. If the system is not disarmed during this delay, an alarm will be
generated. The default Entry Delay is 30 seconds.
E
XIT
D
ELAY
(001 to 255 seconds). The Exit Delay determines the amount of time permit-
ted between entering an Access Code to arm the system and the activation
of an Entry/Exit zone to exit the protected area. The default Exit Delay is 120
seconds.