Cerber
®
C41
H
OOKUP
I
NSTALLATION
& P
ROGRAMMING
M
ANUAL
20
B
ELL
C
UT
-O
FF
(001 to 255 minutes). This sequence of time determines how long the siren
will sound when an alarm is generated. When an alarm is initiated, the siren
will sound for this length of time, or until the alarm is silenced by entering an
Access Code. The default setting is 3 minutes.
EXAMPLE:
The sequences of time should be programmed as follows:
- Entry Delay 10 seconds
- Exit Delay 60 seconds
- Bell Cut-Off 3 minutes
After entering the section by pressing [0][3], enter the sequence:
[0] [1] [0] [0] [6] [0] [0] [0] [3]
After every 3 digits, the keypad buzzer will sound 3 beeps. After the last 3
digits, the keypad buzzer will sound 6 beeps and will exit section [03],
waiting for a new command.
S
ECTION
[04] I
NSTALLER
'
S
C
ODE
The default value for the Installer's Code is [0269]. It is strongly recom-
mended to change this code when the alarm system installation is over.
Keep the new code in a safe place.
Enter 4 digits [X] [X] [X] [X]. After that, the keypad buzzer will sound 6 beeps
and will exit section [04], waiting for a new command.
S
ECTION
[05] P
ROGRAMMABLE
O
UTPUT
O
PTIONS
FOR
PGM1, PGM2
Enter 2 digits.
First digit refers to PGM1 and the second digit refers to PGM2 and they
stand for:
[0] L
ATCH
ON
A
LARM
the output goes to ground in case of alarm and is shut OFF when disarming
[1] F
OLLOW
S
YSTEM
S
TATE
the output goes to ground when arming and is shut OFF when disarming
[2] E
NTRY
D
ELAY
the output goes to ground during the Entry Delay
[3] E
XIT
D
ELAY
the output goes to ground during the Exit Delay