RODCRAFT PNEUMATIC TOOLS
7
Visit our Internet presence at www.rodcraft.com
Here you can also download our manuals.
With further questions contact your nearest Rodcraft branch or the authorized dealer.
GHN300/ GHN600/ GHN1000
Serial: 00001 to 99999
Origin of the product:
Made in China
is in conformity with the requirements of the council Directives on the approximation of the laws of the Member States relating :
to „Machinery“:
2006/42/EC (17/05/2006)
applicable harmonised standard(s) :
EN 1494:2000 + A1:2008
Technical File
available at the
EU Technocenter
CP
ZAC de la Lorie -38, rue Bobby Sands, B.P10273
44818 Saint-Herblain Cedex, France
Place and date of
issue:
44818 Saint-Herblain,
France
21/06/2013
Company name
and address:
Rodcraft Customer Center
Langemarckstr.35 bis
45141 Essen- Germany
Nicolas Lebreton
R&D Manager:
We hereby declare that the following described machine complies with the general safety and health requirements of below mentioned EU directives due to its design and
conception and the type circulated by ourselves. This declaration becomes invalid if the machine is modified without our approval.
Valid for:
EC DECLARATION
EN
6. Maintenance
• The hydraulic unit (pump) is a sealed system, which only requires lubrication of the moving parts under normal working conditions once a month. If
the hydraulic unit was disassembled to replace worn out gaskets, or because oil leaked out, file oil into the pump slowly through the opening of the
oil screw .
• When changing oil, at least once a year, or refiling oil, use oil to file the cylinder up to the oil intake screw. Please make sure that the piston is
retracted.
• All moving parts must be lubricated at regular intervals. Keep the device always clean and away from aggressive chemicals. Do not leave
the jack outdoors.
• The oil level in the tank may not exceed the filing plug position, when the piston is completely retracted.
• Only use hydraulic oil (Type HPL ISO 32) that has been approved by the manufacturer. Caution: Never use brake fluid.
Additionally, oil or lubrication must be applied to mechanical parts every 2 months.
7. Disposal
The disposal of this equipment must be in accordance with the legislation the respective country.
All damaged, strongly worn out or improperly functioning devices HAVE TO BE TAKEN OUT OF OPERATION.
The repair of the equipment should be performed only by qualified technical staff.
Use the equipment only for its intended use as described above, any other use is explicitly excluded! For injuries and damages resulting
from improper use, misuse or infringement of safety instructions, we accept no liability or warranty.
8. CE Certification