User guide
GSM500.GC
Issue 1.00
Page 11
Programming
For a normal usage no specifi c programming is required. But changes and functional
details can be changes this way.
The programming is done using the ECII FLEX emergency phone dial pad, a standard
DTMF phone or by SMS. Following can be programmed:
•
Idle state telephone line voltage;
•
End-of-dial time out;
•
Country identifi cation (international access and country code);
•
Roaming service;
•
Telephone number for SMS notifi cations;
•
Administrator telephone number;
•
Password programming;
•
Battery test;
•
Speech channel receiving level;
•
Speech channel transmitting level.
PLEASE NOTE!
During programming the time between the dial of two digits should be not
longer then 10 seconds. After 10 seconds without digits input you will hear a
warning tone, after this you must hang up and terminate the programming
session.
After each programming you will hear an acknowledge tone if the program-
ming was correct or an error tone if it was wrong. In any case a dial tone will
follow and you can proceed with the programming or dial a telephone number.
The programming can be done also if the devices is not logged on with the
GSM network. In this case after every acknowledge or error tone a missing
GSM network tone will follow. Now you can proceed with the programming or
hang up.
Idle state telephone line voltage
With this programming the idle state voltage on the telephone line which is applied
on the RJ11 plug and the TEL screw connectors can be changed to mach the require-
ment of the connected devices. As default the line voltage is 52 VDC. To change this
value:
DTMF
**61*
<X>
#
SMS
RO-IG5*
<Password (default "0")>
#61*
<X>
#
Where <X> can have the value
0
for 36 VDC line voltage and
1
for 52 VDC line
voltage.
Example DTMF
(36 VDC line voltage)