
Document: 553632
(ICSTT-RM448_EN_P) Issue: 08:
4-5
Step Task
Force
Will remain OFF as the Module boots up (10 to 20 seconds) then stays
OFF until the module has educated.
Aux
Will remain OFF as the Module boots up (10 to 20 seconds) then is
dependent upon data connection.
Serial 1
Will remain OFF as the Module boots up (10 to 20 seconds) then is
dependent upon data connection
Serial 2
Will remain OFF as the Module boots up (10 to 20 seconds) then is
dependent upon data connection
Ethernet 1
Will remain OFF as the Module boots up (10 to 20 seconds) then is
dependent upon data connection
Ethernet 2
Will remain OFF as the Module boots up (10 to 20 seconds) then is
dependent upon data connection
You have to set up the processor IP Address so that the workstation can communicate with the
processor module and download the latest firmware build and configure the processor variables.
3.
Set the Controller IP Address for all the processor modules using the "AADvance Discover
Utility". (Refer to the Configuration Guide for detailed instructions on using the AADvance
Discover Utility Doc. No: 553633).
4.
Install a
Program Enable Key.
Download a valid application and press the FAULT RESET
button. When the application is downloaded and valid the module will display the following
indications:
Valid Application Downloaded
Healthy
GREEN
Ready
GREEN
Run
RED to GREEN (Flashes GREEN as the module educates)
System Healthy
GREEN
Force
GREEN
Aux
Off (Application Dependent)
Serial 1
Dependent on data connection
Serial 2
Dependent on data connection
Ethernet 1
Dependent on data connection
Ethernet 2
Dependent on data connection
Summary of Contents for ics triplex AADvance
Page 7: ......
Page 15: ...Document 553632 ICSTT RM448_EN_P Issue 08 1 5 ...
Page 114: ......
Page 128: ......