Rockwell Automation Publication 440G-UM001A-EN-P — November 2013
27
Description of Operation
Chapter 4
Troubleshooting Series
Circuit
Unit Response Times When
Connected in Series
Green
P
ink
Gr
e
y
Red
Yello
w
W
hit
e
Green
Pink
Gr
ey
Red
Yello
w
W
hit
e
Green
Blue
Pink
Gr
ey
Brow
n
Red
Yello
w
W
hit
e
Green
Pink
Gr
ey
Red
Yello
w
W
hit
e
Green
Pink
Gr
ey
Red
Yello
w
W
hit
e
Blue
Blue
Blue
Blue
Brow
n
Brow
n
Brow
n
Brow
n
+24V
+24V
+24V
+24V
0V
0V
0V
0V
0V
0V
RTN
24V DC
Power
Suppl
y
+24
1606-
XL120D
Lock/Unlock
Lock/Unlock
Lock/Unlock
Lock/Unlock
Lock/Unlock
Recoverable
Fault
Actuator 1 is in sensing range
and guard is locked.
Guard 1 functions properl
y
.
OSSDs are energized to 24V.
Green LED is ON.
Actuator 2 is in sensing range
and guard is locked.
Guard 2 functions properl
y
.
OSSDs are energized to 24V.
Green LED is ON.
Actuator 3 is in sensing
range and guard is locked.
Guard 3 has a fault.
See Diagnostic table.
Red LED is flashing.
Actuator 4 is in sensing range
and guard is locked. Guard
4 functions properl
y
. Series
inputs are 0V. OSSDs are
de-energized to 0V. Green
LED is flashing to indicate
series inputs are not 24V.
Actuator 5 is in sensing range
and guard is locked. Guard 5
functions properl
y
.
Series inputs are 0V. OSSDs
are de-energized to 0V. Green
LED is flashing to indicate
series inputs are not 24V.
OSSDs
are OFF
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
A
c
tuat
or 1
A
c
tuat
or 2
A
c
tuat
or 3
S
wit
ch 1
S
wit
ch 2
S
wit
ch 3
RTN
24V DC
Power
Suppl
y
+24
1606-
XL120D
Gr
een
Pink
Gre
y
Brown
Red
Yel
White
A2
440R-N23132
Initial Conditions:
All switches are
locked
Switch 1 receives
Unlock co
mm
and
(guard can then
be opened).
L
ock/unlock
co
mm
and
Switch 2 drops the 24 volts
(red and
y
ellow) fro
m
switch 1 OSSD outputs.
Green LED flashes.
Switch 3 drops the 24 volts
(red and
y
ellow ) fro
m
switch 3 OSSD outputs.
Green LED flashes.
Pink
Gre
y
Red
Yel
White
Gr
een
Blue
Pink
Gre
y
Red
Yel
White
S11
41
33
23
13
S12
S52
S21 S22
42
34
24
14
A1
S34
200
m
s
150
m
s
100
m
s
0
m
s
650
m
s
625
m
s
600
m
s
0
m
s
Switch 1 guard is
closed
Switch 1 OSSD
outputs are
energized.
Switch 2 OSSD inputs (red
and
y
ellow) transition to
24V DC fro
m
switch 1 OSSD
outputs. Switch 2 OSSD
outputs are energized.
Switch 3 OSSD inputs (red
and
y
ellow) transition to
24V DC fro
m
switch 2
OSSD outputs. Switch 3
OSSD outputs are energized.
Gr
een
Br
own
Blue
Br
own
Blue
Switch 1
Switch 2
Switch 3