Safety Concept
Safety Standards Applied to
the Guardmaster 440G-LZ
Guard Locking Switch
The Guardmaster 440G-LZ satisfies applicable requirements in the
following standards related to functional and machinery assembly:
•
IEC 60947-5-1: 2003+A1: 2009
•
IEC 60947-5-3: 1999/A: 2005
•
IEC 61508:2010 SIL 3
•
IEC 62061:2005 SIL 3
•
EN/ISO 13849-1:2008/AC: 2009 Performance Level e (PLe), Category
4
•
EN/ISO 14119:2013
•
UL 508 17
th
Edition dated 3/19/2013
Introduction
This section describes the safety performance level concept and explains
how the Guardmaster 440G-LZ meets the requirements for SIL 3, Cat. 4 or
Performance Level “e” (PLe) applications.
Safety Certification
The Guardmaster 440G-LZ is certified for use in safety applications up to
and including SIL 3 according to IEC 61508 and IEC 62061 with a proo
f test
interval of 20 years, Performance Level PLe and Category 4 in compliance
with ISO 13849-1.
Safety requirements are based on the standards applicable at the time of
certification.
The TÜV Rheinland group has approved the Guardmaster 440G-LZ for use
in safety-related applications where Performance Level “e” is required for
the door position and lock monitoring functions.
The 440G-LZ must be installed in accordance with the applicable
regulation and standards.
While the 440G-LZ can be used for SIL 3, PLe and Category 4 applications,
the installer must comply with guard requirements (e.g. EN/ISO13854
and EN/ISO 13857) and in some cases also minimum (safe) distance
requirements (e.g. EN/ISO 13855).