Chapter 7
Images Per Read Cycle Limit
Specifies the number of captures to process in a read cycle.
Read Cycle History
Specifies the number of images that can be stored in read cycle history.
Capture Time
Figure 31 - AOP
Figure 32 - WebConnect
Time before First Capture
In almost any moving line application, a time delay is required to confirm that a
symbol is in the field of view of the code reader at the beginning of the capture
sequence.
Time Before First Capture in a moving line application is the time between an
external trigger event and the occurrence of the first capture.
• Default: 5
• Options: 3 and 255
• Default: 10
• Options: 0 and 255
• Default: 0
• Options: 0…65,535 (2.097 seconds, in 32 µs increments)