Rockwell Automation Publication 48CR-UM001A-EN-P - November 2019
159
Specifications
Appendix A
Status Indicators
• Power
• Link (Ethernet)
• Trigger
• Mode
• Pass
• Fail
• Green flash on Good Read
Communication Interface
• Serial
• Ethernet 10/100
• I/O
• Power
Digital I/O
Read Ranges
Table 16 - WVGA High Density
Table 17 - WVGA (Fixed-focus Devices) Standard Density
Table 18 - SXGA (Auto-focus Devices) High Density
Attribute
48CR-CB16R400-E8, 48CR-CB52R102-E8, 48CR-CB80R133-E8, 48CR-CB80R190-E8,
48CR-CC16RAF-E8, 48CR-CC50RAF-E8, 48CRCC77RAF-E8
Inputs
Trigger Input; New Master: Bidirectional, opto-isolated, 4.5…28V rated (10 mA @ 28V DC)
Outputs (1, 2, 3)
Bidirectional, opto-isolated, 1…28V rated
(ICE <100 mA at 24V DC, current limited by user)
Focal Distance
[mm (in.)]
Field of View
[mm (in.)]
Typical 2D Mil
Size
Depth of Field [mm (in.)]
Minimum 2D
Mil Size
Inside
Outside
133 (5.2)
80 (3.1)
15
90 (3.5)
176 (6.9)
10
190 (7.5)
114 (4.5)
20
133 (5.2)
246 (9.7)
15
400 (15.7)
180 (7.1)
30
179 (7.0)
422 (16.6)
30
Focal Distance
[mm (in.)]
Field of View
[mm (in.)]
Typical 2D Mil
Size
Depth of Field [mm (in.)]
Minimum 2D
Mil Size
Inside
Outside
102 (4.0)
94 (3.7)
20
52 (2.0)
152 (6.0)
15
Focal Distance
[mm (in.)]
Field of View
[mm (in.)]
Typical 2D Mil
Size
Depth of Field [mm (in.)]
Minimum 2D
Mil Size
Inside
Outside
133 (5.2)
123 (4.8)
10
88 (3.5)
161 (6.3)
10
190 (7.5)
175 (6.9)
15
115 (4.5)
265 (10.4)
15
400 (15.7)
277 (10.9)
20
224 (8.8)
427 (16.8)
20