The ControlLogix system takes advantage of several networks to allow
communications with many different controllers and devices. The following table
lists which products the ControlLogix controller can communicate with over which
networks.
Controller
EtherNet/IP
ControlNet
DeviceNet
DH+
RS-232 (DF1)
DH-485
1756 ControlLogix yes
yes
yes
yes
yes
yes
1769
CompactLogix
yes
no
yes
no
yes
yes
1789
SoftLogix5800
yes
yes
yes
no
yes
no
1794 FlexLogix
yes
yes
yes
no
yes
yes
5720 PowerFlex
700S with
DriveLogix
yes
yes
yes
no
yes
yes
1785 PLC-5
yes
✶
†
yes
yes‡
yes
yes
na
1747 SLC
yes§
yes
yes
♣
yes
♣
yes
no
1761 MicroLogix
yes
no
yes
♣
no
yes
no
1762 MicroLogix
yes
no
yes
♣
no
yes
no
1769 MicroLogix
yes
no
yes
♣
no
yes
no
1772 PLC-2
na
na
na
yes
➤
yes
a
na
1775 PLC-3
na
na
na
yes
yes
na
5250 PLC-5/250
na
na
no
yes
yes
na
✶
The Ethernet PLC-5 processor must be one of these:
series C, revision N.1 or later
series D, revision E.1 or later
series E, revision D.1 or later
†The 1785-ENET Ethernet communication interface module must be series A, revision D or later.
‡The PLC-5, SLC, and MicroLogix processors appear as I/O points to the Logix controller. Requires 1761-NET-DNI DeviceNet interface.
§Use a 1747-L55x controller with OS501 or greater.
♣
Use a 1747-L54x controller.
➤
The PLC-2 controller requires a 1785-KA module for DH+ communications.
a
The PLC-2 controller requires a 1771-KG module for serial (DF1) communications.
The PLC-3 controller requires a 1775-S5 module for DH+ communications.
The PLC-3 controller requires a 1775-KA module for serial (DF1) communications.
Communication Device
9355 RSLinx
software
1784-KTC, -KTCx, -
KTCx15, -PCIC(S),
-PCC
1784-PCIDS, -PCD
1784-KTX, -KTXD,
-PCMK
1788-CN2DN
1788-EN2DN
1788-CN2FF
1203-CN1
ControlNet module
1203-FM1/FB1
SCANport
✶
Use the generic module configuration to configure the 1203-CN1 module and a CIP generic MSG instruction to communicate with the module.
†Use a CIP generic MSG instruction to communicate with the 1203-FM1 SCANport module on a DIN rail that is remote to the controller. The remote DIN rail also requires a 1794-ACN(R)15 ControlNet adapter module.
EtherNet/IP
yes
na
na
na
na
yes
na
na
na
ControlNet
yes
yes
na
na
yes
na
yes
yes
✶
yes†
DeviceNet
no
na
yes
na
yes
yes
na
na
na
DH+
yes
na
na
yes
na
na
na
na
na
RS-232 (DF1)
yes
na
na
na
na
na
na
na
na
DH-485
no
na
na
na
na
na
na
na
na
Summary of Contents for 1756-L55M12
Page 1: ...ControlLogix Selection Guide 1756 L55 1756 L61 1756 L62 1756 L63 1756 L60M03SE...
Page 67: ...65 1756 SG001G EN P March 2004 1756 A7 with power supply 1756 A10 with power supply...
Page 68: ...66 1756 SG001G EN P March 2004 1756 A13 with power supply 1756 A17 with power supply...
Page 72: ...70 1756 SG001G EN P March 2004 Power load and transformer sizing...
Page 85: ...83 1756 SG001G EN P March 2004 Notes...
Page 86: ...84 1756 SG001G EN P March 2004 Notes...
Page 87: ......