1756-SG001G-EN-P — March 2004
AIFMs for 1756 analog input modules
AIFMs for 1756 analog output modules
Cat. No.
Type of
AIFM
Descripti
on
IF6I
IF6I
IF8 single-end
IF8 differential
IF16 single-end
IF16 differential
IR6I
IT6I
current
voltage
voltage
current
voltage
current
voltage
current
voltage
current
1492-AIFM4-3
feed
through
4 channels
with 3
terminals/c
hannel
1492-AIFM6S-3
feed
through
6 channels
isolated
with 3-4
terminals/c
hannel
X
Y
Z
1492-AIFM8-3
feed
through
8 channels
with 3
terminals/c
hannel
TA
TB
TC
TD
UA
UB
UC
UD
1492-AIFM6TC-3
thermo
couple
6 channels
with 3
terminals/c
hannel
Y
1492-AIFM8-F-5
fusible
8 channels
with 5
terminals/c
hannel
TA
TB
TC
TD
1492-AIFM16-F-3 fusible
16
channels
with 3
terminals/c
hannel
UA
UB
UC
UD
1492-AIFM16-F-5 fusible
16
channels
with 5
terminals/c
hannel
UA
UB
UC
UD
Find the column for the analog I/O module. Follow the column own to see what AIFMs are compatible with the I/O module as indicated by a letter code. When you select the AIFM, use the letter code from this chart to find the
compatible cable in the following table for analog pre-wired cable. The letter code must match the last character of the catalog number for the cable.
Cat. No.
Type of AIFM
Description
IR6I
IT6I
OF4 (voltage)
OF4 (current)
OF6CI
OF6VI
OF8 (voltage)
OF8 (current)
1492-AIFM4-3
feed through
4 channels with
3
terminals/chann
el
VA
VB
1492-AIFM6S-3
feed through
6 channels
isolated with 3-4
terminals/chann
el
Z
Y
Y
1492-AIFM8-3
feed through
8 channels with
3
terminals/chann
el
WA
WB
1492-AIFM6TC-3 thermocouple
6 channels with
3
terminals/chann
el
Y
1492-AIFM8-F-5
fusible
8 channels with
5
terminals/chann
el
1492-AIFM16-F-3 fusible
16 channels with
3
terminals/chann
el
1492-AIFM16-F-5 fusible
16 channels with
5
terminals/chann
el
Find the column for the analog I/O module. Follow the column own to see what AIFMs are compatible with the I/O module as indicated by a letter code. When you select the AIFM, use the letter code from this chart to find the
compatible cable in the following table for analog pre-wired cable. The letter code must match the last character of the catalog number for the cable.
Summary of Contents for 1756-L55M12
Page 1: ...ControlLogix Selection Guide 1756 L55 1756 L61 1756 L62 1756 L63 1756 L60M03SE...
Page 67: ...65 1756 SG001G EN P March 2004 1756 A7 with power supply 1756 A10 with power supply...
Page 68: ...66 1756 SG001G EN P March 2004 1756 A13 with power supply 1756 A17 with power supply...
Page 72: ...70 1756 SG001G EN P March 2004 Power load and transformer sizing...
Page 85: ...83 1756 SG001G EN P March 2004 Notes...
Page 86: ...84 1756 SG001G EN P March 2004 Notes...
Page 87: ......