background image

7

Check Rockler.com for updates. If you have further questions, please

contact our Technical Support Department at 1-800-260-9663  

or [email protected]

 1.  Orient the Upper Tube so that the top end (without the 

    grain-alignment mark) is facing up. Apply epoxy to the rim 

    inside the top end of the Upper Tube and fit the Top Cap into 

    it. Use a clamp or pen press if the fit is tight. Make sure the 

    turned blank is flush with the Top Cap. Remove any 

    squeeze-out from outside and inside the tubes immediately, 

    and allow the adhesive to fully cure.

 

2.  Apply epoxy to the rim inside the bottom end of the Upper 

    Tube and fit it onto the Coupler Ring. Make sure that the 

    upper blank is flush with the Coupler Ring. Use a clamp or 

    pen press if the fit is tight. Remove any squeeze-out from 

    outside and inside the tubes immediately (especially from the

   threads). 

Fig. 6.

 

3.  Once the adhesive applied in Step 2 has fully cured, thread 

    the Upper Tube assembly onto the Hygrometer Collar. 

 

4.  Apply epoxy to the rim inside the non-threaded end of the 

    Lower Tube (the one with the grain-alignment mark) and 

    fit the non-threaded end of the Hygrometer Collar into it. 

    Use a clamp or pen press to bring the pieces together if the 

    fit is tight. Rotate the Lower Tube, if necessary, to make sure 

    that the grain-alignment marks match up. Also make sure 

    that the turned blank is flush with the Hygrometer Collar. 

    Carefully unthread the Upper Tube assembly and remove any 

    squeeze-out from outside and inside the tubes immediately. 

    Allow the adhesive to fully cure . 

Fig. 7.

 

5.  Thread the Bottom Cap into the Lower Tube, and remove the 

    tape with the grain-alignment marks.

Fig. 7

Fig. 6

Fig. 8

Regulating Humidity Inside the Tube

The Bottom Cap is designed to enable you to achieve the relative 

humidity desired for your cigar. It incorporates an absorbent foam 

disk held in place by a filter and a platform that keeps the cigar 

from wicking up excessive moisture.

To “load” the hydrating disk, simply place a few drops of cigar 

humidifier solution or distilled water onto the filter through the 

openings in the platform. 

Fig. 8. Tip the Bottom Cap or use 

a paper towel or cotton swab to remove any pooled moisture. 

Thread the Bottom Cap onto the Lower Tube and then check the 

Hygrometer Collar to determine the relative humidity. If you want 

a higher humidity, continue adding drops of fluid until the desired 

humidity is reached. If you want a lower humidity, unscrew the 

Bottom Cap and allow some moisture to evaporate.

Upper Tube

Top Cap

Coupler Ring

Align marks

 

For smoother threading of the Upper 

Tube and Bottom Cap during use, apply a small amount of 

parrafin wax to the threads.

Summary of Contents for GRP40589

Page 1: ...structions prior to use for important safety information Always check Rockler com to confirm that you are using the most recent manual version for your product Cigar Humidor Turning Kit Instructions E...

Page 2: ...wner s manual Do not use this product until you have read and are confident you understand Product Specific Safety Warnings p 3 Supplies Needed p 4 Blank Preparation pp 4 5 Turning the Blanks p 6 Asse...

Page 3: ...eat buildup during drilling could lead to cracking of the blank sections To minimize heat buildup drill about 1 4 1 2 at a time regularly backing out the bit to clear the chips Also stop 1 8 short of...

Page 4: ...the hole down the center of the blank stopping 1 8 short of the bottom 7 Repeat Steps 5 and 6 to drill out the center of the other blank section 8 Cut away the 1 8 left at the closed end of each blank...

Page 5: ...12 Using a disk or belt sander sand the ends of the blank sections square Sand right up to the tubes but take care not to sand off the finish The ends must be square to the tubes and parallel with ea...

Page 6: ...ner grits of sandpaper 180 240 320 400 and 600 to bring the blanks flush with the bushings and smooth them for finishing 5 Apply the desired finish and polish 6 Remove the blanks from the mandrel 7 To...

Page 7: ...te the Lower Tube if necessary to make sure that the grain alignment marks match up Also make sure that the turned blank is flush with the Hygrometer Collar Carefully unthread the Upper Tube assembly...

Page 8: ...Distributed by Rockler Companies Inc Medina MN 55340 52103 Rev 08 18...

Reviews: