S
OURCE
U
NIT
I
NSTALLATION
• Mount the Installation Sleeve into a secure instrument panel
• Bend Tabs on the installation sleeve which correspond to the chart above
• Bend Appropriate Tabs on all sides of the mounting sleeve (Top, Bottom,
Left & Right)
Source Unit Mounting Angle
Instrument Panel Thickness
Tabs to Bend
A
B
C
D
E
F
G
1.2mm to 2.5mm
x
x
x
2.4mm to 3.5mm
x
x
x
3.6mm to 4.5mm
x
x
4.6mm to 5.5mm
x
x
x
5.6mm to 7.0mm
x
x
7.0mm to 12mm
x
x
x
12.0mm to 15mm
x
x
Top View
Right
Side View
Left
Side View
G
G
C
C
C
B
F
A
D
E
E
D
A
F
B
C
– 19 –
I
N
S
T
A
L
L
A
T
I
O
N
®
®
20
°
20
°
Mounting the Installation Sleeve
• Mount the Installation Sleeve as close to horizontal as possible for
optimum performance
• Mounting Angles up to
±
20
°
from horizontal can be accommodated