22
Motion Control™ DNA Damper Service
M o t i o n C o n t r o l ™ D N A D a m p e r S e r v i c e
2 0 0 H o u r S e r v i c e
D a m p e r S e r v i c e
Crown Adjust
: Rotate the adjuster knob to the open position.
RL:
Remove the retention screw and knob.
RCT3:
Remove the set screw, nut, and knob.
RL Remote:
Press the remote lever in to the open position. Remove the
retention screw, cable spool, and cable. Loosen the remote cable stop
collar clamping bolt. Remove the cable stop collar.
Loosen the compression damper top cap.
Remove the compression damper by pulling up firmly and slowly, while
gently rotating the damper in a circular motion.
NOTICE
Do not force the damper out of the upper tube if there is resistance. This
can cause separation of the piston from the damper tube.
2.5 mm
RL
RL
1 a
1.5 mm
RCT3
10 mm
RCT3
1 b
2.5 mm
RL Remote
2 mm
RL Remote
2
24 mm
24 mm