13
6.2.4 Painting.
The heatproof paint that covers the inside and outside of the appliance withstands temperatures up to 600 °C and
releases a subtle typical smell that disappears after the first few uses.
It is possible for the paint to jump out in some areas inside the housing after a period of use, due to corrosion caused by liquids,
inadequate fuel types or others not authorized by the manufacturer, etc., In that case it will be necessary to repaint all damaged areas
before a prolonged shutdown period.
Use exclusively "Rocal heatproof spray paint”.
Rocal offers various optional items, contact your local dealer to purchase these items. Some of the items are shown below:
Item
Code
Description
ECOntrol
C7000
Intelligent combustion control
Log store
E2150-2
Ash vaccum cleaner
ASPIRADOR
Bench
Wall support
E2120-1
Below is a table of possible anomalies, their causes and solutions:
PROBLEM
CAUSE
SOLUTION
1. Rejects smoke and / or
insufficient draught
Incorrect duct
Lack of air supply for combustion
Incorrect position of registers
Dirty flue duct
Duct servicing*:
-connection
-diameter
-leaks
-insufficient length
-outdoor access
-possible elements blocking the exit
Check vents and / or outside air supply.
Simultaneous operation with other ventilation
devices and / or heating
Setting the register
Contact a professional to clean flue duct. If the
problem persists, contact your dealer.
2.
Excessive dirt on glass
Incorrect duct
Inappropriate fuel
Overly closed registers
Revise section on insufficient flue (below).
Use recommended fuel
Adjust registers
3. Glass bleaching or
colour fading of the plate
Excessive temperature caused by excessive
heat in the combustion chamber
Check the fuel load avoiding overheating
Adjust registers
4. Poor heating
Inappropriate fuel
Insufficient load
Combustion control registers in the wrong
position
Use recommended fuel
Adding fuel
Adjust register
5. Venting smoke and / or
gases from the front, bad
smell
First lighting
Flammable or combustible items in the
enclosure or surrounding walls of the
equipment
Crack in the combustion chamber of the
equipment
Wait for the polymerization process of the paint to
finish; this can take from one to several lightings.
Review of insulating materials such as fiberglass,
fireproof wood or any inflammable elements and
replace them.
Check for tightness and if you discover a crack,
please contact your dealer.
6. Excessive draft
Incorrect duct
Combustion control registers in the wrong
position
Duct servicing
- Excessive length
- Check Depression
- Incorrect diameter
- Check door gasket
7. OPTIONAL COMPLEMENTS
8. PROBLEMS: CAUSE AND SOLUTION
Summary of Contents for Habit 76 +T
Page 34: ......
Page 35: ...1 ANEXO ANNEX ANNEXE ANESSO I mm Habit 76 LD T Habit 76 LI T A 755 B 567 F 430 G 143 H 180...
Page 36: ...2 II 1 2 6 4 8 3 10 9 7 5...
Page 37: ...3 III 1 2 3 4 A B...
Page 38: ...4 III C A 1 A 2 A 3 A 4 A 5...
Page 39: ...5 III A 6 A 7 A 8 B 1 B 2 B 3...
Page 40: ...6 III B 4 B 5 B 6 B 7 B 8 C 1...
Page 41: ...7 III C 2 C 3...
Page 42: ...8 IV D 1 D 2 D 3 D 4 D 5 D 6...
Page 43: ...9 IV D 7 D 8 D 9 D 10 D 11 D 12...
Page 44: ...10 IV D 13 D 14 D 15 D 16 D 17 D 18...
Page 45: ...11 IV D 19 D 20 D 21 D 22 D 23 D 24...
Page 46: ...12 IV D 25 D 26...