10
1.1 Technical specifications
1.2 Breakdown of delivery components
(Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1.
Fireplace’s body.
2.
Heat-resistant spray paint for touch-ups.
3.
Fire grate.
4.
Heat-resistant glove.
5.
Draught limtier
6.
Cleaning cloth
7.
Exterior air inlet kit. (Exterior air inlet connector, connector support, tubular joint, metallic anchor, screws and nuts)
8.
Tool for handling registers and opening door.
9.
Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.
10.
+T
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I, page 1.
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH UPON
INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground.
Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2.2 Flue liner.
It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside in observation
of the smoke pipe diameter.
The good condition and suitability of this smoke pipe must be certified by a professional and
must also observe the relevant national regulations
. This flue liner must be T400 and G type should not be shared with other
Parameter
Model
Habit 76 LD +T | Habit 76 LI +T
Minimum - Maximum draught
11-13 Pa
Fuel consumption
2,8 kg/h
Smoke mass flow rate
10,8 g/s
Efficiency
77,3 %
Nominal output
9,4 kW
Power range
6,5 – 11 kW
Average CO concentration at 13% of O2
0,08 %
NOx concentration at 13% of O2
104 mg/Nm
3
OGC concentration at 13% of O2
66 mg/Nm
3
Particle concentration at 13% of O2
16,4 mg/Nm
3
Medium draft (trial)
11,2 Pa
Net weight
153,9 kg
Maximum authorized load (fuel)
4 kg
Reload height
200 mm
Logs length
400 mm
Minimum flue height
4000 mm
Ø Flue duct
180 mm
Ø Air inlet
100 mm
Outer fireplace safety distances (back)
200 mm
Outer fireplace safety distances (side)
200 mm
Outer fireplace safety distances (glass side)
1000 mm
Outer fireplace safety distances (frontal)
1000 mm
Cableado eléctrico de conexión
Silicone hose 3*wire of 1.5 mm
2
Flujo aire turbinas (unidad)
135 m
3
/h
Potencia turbinas (unidad)
20 W
Distancia seguridad mín. a las salidas de aire
250 mm
Temperatura media de humos
270 ºC
Tipo de combustión
INTERMITENT
Conducto
NOT SHARED
Combustible
NATURAL WOOD
Humedad leños combustible
12-20 % - two years under cover
Año Certificación
2019
Nº de Certificado
1880-CPR-014-19
1. SPECIFICATIONS
2. REQUIREMENTS PRIOR TO INSTALLATION
Summary of Contents for Habit 76 +T
Page 34: ......
Page 35: ...1 ANEXO ANNEX ANNEXE ANESSO I mm Habit 76 LD T Habit 76 LI T A 755 B 567 F 430 G 143 H 180...
Page 36: ...2 II 1 2 6 4 8 3 10 9 7 5...
Page 37: ...3 III 1 2 3 4 A B...
Page 38: ...4 III C A 1 A 2 A 3 A 4 A 5...
Page 39: ...5 III A 6 A 7 A 8 B 1 B 2 B 3...
Page 40: ...6 III B 4 B 5 B 6 B 7 B 8 C 1...
Page 41: ...7 III C 2 C 3...
Page 42: ...8 IV D 1 D 2 D 3 D 4 D 5 D 6...
Page 43: ...9 IV D 7 D 8 D 9 D 10 D 11 D 12...
Page 44: ...10 IV D 13 D 14 D 15 D 16 D 17 D 18...
Page 45: ...11 IV D 19 D 20 D 21 D 22 D 23 D 24...
Page 46: ...12 IV D 25 D 26...