The table below shows the possible malfunctions, what brought them about and
the solutions to follow
:
MALFUNCTION
CAUSE
SOLUTION
1.
Smoke
mislead
or
insufficient air intake.
Inadequate pipe.
Insufficient air for combustion
Check pipe:
-connection
-diameter
-leaks
-insufficient length
-outlet
-blockage
Check the flue draught entry
Other ventilation or heating device work
simultaneously
2. Glass (too dirty)
Inadequate pipe.
Inadequate fuel.
Upper deflected panel misadjusted
Check pipe
Use authorized fuel
Adjust according directions
3. Whitening of the glass or
damage the color of the
plate
Excess temperature caused by an
excessive fire in the combustion
chamber
Check the fuel load
Set the registers according to paragraph 2.2.
4. Little heating
Inadequate fuel.
Inadequate air inlet to smokestack
Authorized fuel
Check chamber and seal to the flue
5. Smoke going out through
front door.
First lit.
Flammable or combustible elements
inside the fireplace or around.
Crack in the flue.
Upper deflected panel misadjusted
Wait for the polymerisation process (more than
one lit)
Check insulation material (glass fibre, igneous
wood or other elements), possibly replace
them
Check for cracks and call dealer
Adjust according directions.
6. Malfunction of opening
mechanism.
Blockage of the mechanism.
Free the door and close it some centimetres.
7. Door moves itself.
Misadjusted counterweight.
Remove front frame and add or subtract
weight.
8. Cracks in some parts of
vermiculite inside
Beat in one of the pieces performed,
especially at the time of recharge
Try not to pull the logs but put
Perform charging where the temperature of the
combustion chamber has decreased
NOTE: If the part is only cracked but does
not move from your site, you can continue
using the device with absolute normality
(see section 2.6. Loading and refueling)
4. DETECTION OF MALFUNCTION