Are forbidden other fuels, including liquid (sometimes used to start the fire).

 

The  maximum  length  of  the  logs  should  not  exceed  the  length  specified  in  the 
technical data according to model (see Table: Technical characteristics).

 

2.6. Loading and reload fuel. It must take into account the maximum authorised 
load  of  fuel,  ensuring  that  when  the  recharge.  The  fuel  can’t  overtake  the  limit, 
taking  care  not  to  exceed  either  in  quantity  or  size  to  the  data  specified  above 
(you can see the Technical Characteristics). 

 

IMPORTANT NOTE: 
 
Interior parts vermiculite SHOULD NOT BE HIT, especially when done 
refueling.  
If any of these parts are cracked, but is properly placed in your site, does 
not alter the proper functioning of NI A POTENTIAL RISK. 
The device can be 
used normally.  
These  cracks  do  not  pose  any  manufacturing  defects  so  you  do  not  fall  under 
warranty. 

 

 

To make the procedure ignition follow these steps: placing the burden on the 
central area of the database from home, open the register primary and secondary 
maximum and then fire pledge (USE ONLY FOR THE ELEMENTS TO). Once the 
fire is lit, close the primary register to prevent excessive combustion and control 
the intensity by the secondary registers (you can see point 2.2. Fire control). 
 When the fuel load is reduced you will have to recharge considering data 
specified above. 
2.7.  Mechanism  blockage.
  It  is  compulsory  to  check  any  piece  because  they 
might get stuck after a long period of time without using the fireplace.  
It is also advisable to review the outdoor air intakes that supply air for combustion, 
they should be free of blockage.  
2.8. Load opening.  
2.8.1. Guillotine opening: 
in this system, the door moves from down to upwards 
and it is useful for loading. 
2.8.2.
  Swing  opening  (C23).  This  function  is  used  for  the  cleaning  or  changing 
glass,  seals  etc.  To  open  the  doors,  use  specific  tool,  rocking  it  on  the  upper 
frame and pulling to the left so the door moves down.  
2.9.
 Cleaning and maintenance 
2.9.1.
 Glass cleaning. To clean the glass, the apparatus must not be operating. 
Do not clean with any liquid either the metal parts of the door or the seal, in order 
to prevent damage.  
2.9.2.
  Ash  box  cleaning.  Empty  the  ash  box  when  the  apparatus  is  totally  off. 
Watch out hot ash. When doing it, dump the ash into a metal bucket. 
The extraction of this tray can be performed by the top (C24) or the bottom (C25).

  

 

For this last option, the possibility of acquiring a small door with grid – 

See 

in paragraph E-2 Optional complements

 - check with your Rocal distributer) 

Summary of Contents for G 505

Page 1: ...Sant Antoni N 2 08540 Centelles Barcelona Spain N I F A 58618380 G 505 C DIGO CODE CODE M1755 MANUAL DE CARACTERISTICAS INSTALACION Y FUNCIONAMIENTO USER S GUIDE ON CHARACTERISTICS ASSEMBLY AND OPERA...

Page 2: ...Y MEDIDAS C FOTOS MONTAJE D DESPIECE RECAMBIOS 1 VRM1755 3 2 piezas Placa deflectora superior lateral izquierda 2 VRM1755 4 2 piezas Placa deflectora superior central izquierda 3 VRM1755 4 2 piezas Pl...

Page 3: ...m nma del conducto 4000 mm Conducto salida humos 250 mm Conductos salida aire 120 mm Conductos toma aire exterior 100 mm Distancia interior nicho hogar Frontal 10 mm Distancia interior nicho hogar Tra...

Page 4: ...uerta en sistema basculante en el marco del m dulo justo en medio por la parte interior encontrar dos tornillos afl jelos y a ada o quite peso para equilibrar la puerta seg n convenga Una vez equilibr...

Page 5: ...trav s de un conector situado en la parte inferior trasera del m dulo C11 Esta toma puede ser del exterior de la vivienda garaje o s tano ventilados Si no se realiza esta entrada del exterior este ada...

Page 6: ...a colocar el marco ajustando los correspondientes tornillos hasta que el marco quede totalmente acoplado a la obra 1 11 Interior del hogar 1 11 1 Colocaci n de las piezas de vermiculita del interior...

Page 7: ...ensidad de la combusti n Hay que evitar una combusti n excesiva y un exceso de temperatura en la c mara de combusti n Uno de los s ntomas de este exceso de temperatura es el blanqueamiento del cristal...

Page 8: ...rant a Para efectuar el procedimiento de encendido siga los pasos siguientes coloque la carga en la zona central de la base del hogar abrir el registro primario y secundario al m ximo y a continuaci n...

Page 9: ...os Es posible que en algunas zonas del interior del hogar despu s de un tiempo de uso la pintura acabe por desaparecer debido a la corrosi n por l quidos tipos de combustibles inadecuados u otros que...

Page 10: ...arco con retornos encaj ndolo desde la parte inferior E2 E3 E4 E5 E6 E7 3 1 2 Sujeci n del marco Atornille los tornillos que encontrar en la parte interna inferior del aparato E8 seguidamente atornill...

Page 11: ...s encendidos Elementos combustibles o inflamables en el recinto o paredes circundantes al aparato Grieta en la c mara de combusti n del aparato Esperar que el proceso de polimerizaci n de la pintura f...

Page 12: ...E RECAMBIO ATENCI N Todas las pruebas han sido realizadas siguiendo la Normativa UNE EN 13229 2002 UNE EN 13229 2002 A2 2005 UNE EN 13229 2002 AC 2006 UNE EN 13229 2002 A2 2005 AC 2007 La revisi n del...

Page 13: ...e 13 Air outlet adapters B DIAGRAMS AND SIZE C ASSEMBLY PICTURES D SPARE PARTS PICTURES 1 VRM1755 3 Left top deflected panel 2 VRM1755 4 Central left top deflected panel 3 VRM1755 4 Central right top...

Page 14: ...00 mm Minimum height of pipe 4000 mm Flue duct 250 mm Air conect pieces 120 mm Air outlet 100 mm Inner fireplace room safety distances frontal 10 mm Inner fireplace safety distances back 20 mm Inner f...

Page 15: ...mbled on floors which provide an adequate bearing capacity If the resistance is not enough a panel of balance would be required to distribute the whole weight of the fireplace 1 5 Foot platform C4 C5...

Page 16: ...room The appliance is provided with an air intake if this input is not connected is necessary to provide an air intake in the same room of a diameter not less than 80 mm and take into account the sim...

Page 17: ...ed and once installation is complete it must be replaced C14 C15 C16 C17 C18 1 12 Deflected panels assembly 1 12 1 Upper side plates C19 C20 These two plates have three shooting positions to graduate...

Page 18: ...ve combustion and excess temperature in the combustion chamber One symptom of this excess of temperature is the whitening of the glass Keep in mind that the registration is closed secondary more dirt...

Page 19: ...tion and control the intensity by the secondary registers you can see point 2 2 Fire control When the fuel load is reduced you will have to recharge considering data specified above 2 7 Mechanism bloc...

Page 20: ...It is possible that under certain weather conditions the apparatus doesn t work properly smoke mislead or not enough intake When observing these phenomena it is highly recommended to close all air reg...

Page 21: ...eck chamber and seal to the flue 5 Smoke going out through front door First lit Flammable or combustible elements inside the fireplace or around Crack in the flue Upper deflected panel misadjusted Wai...

Page 22: ...A2 2005 2002 AC 2006 2002 A2 2005 AC 2007 Fit in devices and mechanisms including fireplaces which may use solid fuel Requirements and methods for test UNE EN 60335 Checking and replacing of installa...

Page 23: ...CROQUIS ET MESURES C PHOTOS MONTAGE D PI CES DE RECHANGE 1 VRM1755 3 Plaque d flecteur sup rieur gauche 2 VRM1755 4 Plaque d flecteur sup rieur centrale gauche 3 VRM1755 4 Plaque d flecteur sup rieur...

Page 24: ...teur minimale de conduit 4000 mm Conduit sortie des fum es 250 mm Conduit sorties d air 120 mm Conduit prise l air ext rieur 100 mm Distance int rieur du caisson Frontal 10 mm Distance int rieur du ca...

Page 25: ...vrir la porte en syst me basculant la partie int rieur du cadre du foyer devisser les deux vis et enlever ou ajouter du poids afin d quilibrer la porte Une fois quilibr e puis fermez la porte et v rif...

Page 26: ...necteur situ dans la partie inf rieure du module C11 Cette prise peut provenir de l ext rieur du logement garage ou du sous sol a r s Si cette prise de l ext rieur n est pas r alis e cet adaptateur ne...

Page 27: ...ez remplacer le cadre en ajustant les vis jusqu ce que le cadre est fix 1 11 Int rieur du foyer 1 11 1 Pose des plaques de vermiculite l int rieur du foyer Les pi ces de vermiculite sont plac es l usi...

Page 28: ...anette est identifi e par une flamme de feu 2 2 2 R glage d air du secondaire C22 Elle est situ e dans le c t droit de l appareil Elle sert mesurer et maintenir l intensit de la combustion Il faut vit...

Page 29: ...RMALEMENT Ces fissures ne repr sentent aucun d faut de fabrication donc ne sont pas sous garantie Allumage placer la charge sur la zone centrale du foyer ouvrir le registre primaire au maximum et allu...

Page 30: ...ertain usage la peinture disparaisse certains endroits l int rieur du foyer cause de la corrosion produite par des liquides de nettoyage on des combustible inad quats ou autres que les combustibles au...

Page 31: ...pareil placer le cadre avec le trac de revient de la partie inf rieure E2 E3 E4 E5 E6 E7 3 1 2 Fixation du cadre Serrer les vis de trouver le fond l int rieur de l appareil E8 puis serrer les vis four...

Page 32: ...air incontr l e possible 5 Sortie de fum e ou gaz par les grilles de ventilation Primiers feux El ments combustibles ou inflamables dans l habillage ou proximit Fissure dans la chambre combustion ou...

Page 33: ...rme UNE EN 13229 2002 A1 2003 2002 A2 2005 2002 AC 2006 2002 A2 2005 AC 2007 Appareils ins rables inclus les foyers ouverts qui utilisent combustibles solides Conditions requises et m thodes d essai U...

Reviews: