13
5.2.3. Flue liner.
It is important to keep the flue liner clean. It gets dirty depending on the fuel used, on a slower or faster combustion,
etc. You need to clean the flue liner at least once per season. It is mandatory for a specialist to review it periodically. To access the
flue liner follow the steps shown in pictures “D.9”, “D.10” and “D.11” of the ANNEXED document.
5.2.4. Painting.
The heat-resistant paint that covers the whole device (the combustion chamber, the interior, the front door, the
frame which covers the joints, etc.), resists up to 600ºC of temperature and releases a slight characteristic odor that disappears with
the first ignitions. It is necessary to regularly check the condition of the paint and correct it when necessary.
This paint can be damaged when; the temperature exceeds 600ºC, fuels with too much humidity or non-recommended fuels are used,
it is installed in humid environments and / or salinity in the environment (seawater), it is in contact with chemical cleaning products or
with water (inputs through the duct, etc.).
Use exclusively "Rocal heatproof spray paint”.
Rocal offers various optional items, contact your local dealer to purchase these items. Some of the items are shown below:
Item
Code
Description
ECOntrol
C7000
Intelligent combustion control
4 sides frame
*****
Four side frame of 4 cm
Decorative frame NERO
*****
Four frame sides of 10 cm with decoration NERO
Log store
C1000
Ash vaccum cleaner
ASPIRADOR
1 inlet diffuser
D0001
1 inlet narrow diffuser
D0002
2 inlets diffuser
D0006
2 inlet snarrow diffuser
D0007
3 inlets diffuser
D0011
4 inlets diffuser
D0016
1 exit diffuser
D1001
1 exit narrow diffuser
D1002
2 exits diffuser
D1006
2 exits narrow diffuser
D1007
3 exits diffuser
D1011
4 exits diffuser
D1016
Below is a table of possible anomalies, their causes and solutions:
PROBLEM
CAUSE
SOLUTION
7 PROBLEMS: CAUSE AND SOLUTION
CAUTION: With the appliance running, the inside compartment must remain completely closed.
You can only access it for ash disposal.
6. OPTIONAL COMPLEMENTS
Summary of Contents for G 450 DC
Page 38: ...1 ANEXO ANNEX ANNEXE ANESSO I...
Page 39: ...2 II 1 10 11 9 4 2 5 3 6 7 8 13 12...
Page 40: ...3 III 1 2...
Page 41: ...4 III 1 2 3 4 5 6...
Page 42: ...5 III 7 8 8 A 1 A 2 A 3...
Page 43: ...6 III A 5 B 1 B 2 B 3 B 4 B 5...
Page 44: ...7 III B 6 B 7 B 8 C 1 C 2...
Page 45: ...8 IV D 1 D 2 D 3 D 4 D 5 D 6...
Page 46: ...9 IV D 7 D 8 D 9 D 10 D 11 D 12...
Page 47: ...10 D 13...