4.2 Pilot fire lighting. 

For a reasonable period of time, approximately 24 hours, it must not exceed 50% of the Maximum load allowed 

by the manufacturer. Before lighting the fire, ensure that nothing delivered with the equipment has stayed inside (such as gloves, 

spray paint ...) 

 

4.3. Combustion control. 

The appliance has mechanisms to regulate combustion. 

  

4.3.1. Primary register. 

The primary register is used to control the air intake which comes into the combustion chamber to the base 

of the fire through the vermiculite at the back. The primary damper should be used mainly for ignition and, if necessary, as a help 

for the combustion. To locate the control handle of the register and its use, see picture ‘D.7’ from the ANNEX document. 

 

4.3.2. Secondary register. 

The secondary register is used to control the air entering the combustion chamber from the top. The 

secondary register is used as combustion intensity adjustment. To locate the register control handle and to know how to use it see 

picture "D.8” of the ANNEXED document.

  

4.4 Fire lighting.

 To light the fire, use suitable materials for this purpose, such as heat pads, paper, dry and thin branches. 

DO NOT 

USE GASOLINE, SOLVENTS OR ALCOHOL

. To see the correct position, see picture "D.4" of the ANNEXED document, then light 

the fire using a suitable material. Once the fire is lit keep the door and the registers open for a reasonable time to prevent condensation 

on the door. When the apparatus is hot enough close the door, adjust the primary register to avoid excessive combustion and control 
the intensity of fire by the child record. 

  

 

 

4.5 Loading and reloading of fuel.

 Do not exceed the maximum allowed load or reload. (See Table of Technical specifications). 

 

4.6  Door  opening.

  The  door  must  be  opened  only  for  reloading.  To  open  it,  follow  the  steps  described  in  picture  "D.1"  of  the 

ANNEXED document.

 

 

4.7 Operation in adverse weather conditions. 

It is possible for the device to malfunction due to sudden or unexpected weather 

changes, causing: low pressure, ebb currents of air into the smoke duct. When these phenomena are observed it is advisable to close 

the combustion register and turn the equipment off. 
 

4.8 Fire Prevention. 

You must not place any flammable element outside the safety distance from the fireplace described in the table 

in section 1.1 Technical specifications. You shall also take special precautions if there are children and elderly people present. In 

case of fire, push away all the people around it, close the registers as much as possible and notify the Firefighting service. 

4.9 Dilations of the sheet.

 

Materials subject to temperature changes undergo dilatations. This phenomenon can cause sporadic 

metallic noises more or less frequently. These are completely innocuous and do not mean any risk or problem for its operation. 

 

 

5.1 Maintenance. 

An appropriate and regular maintenance of both the appliance and the installation contributes greatly to its good 

performance. It is important to perform periodic and complete controls of the equipment and of the ducts and installation. Thus, for 

your safety and comfort, 

some of our dealers offer a servicing contract for your device. Please contact your dealer for this 

service. 
 

5.1.1 Locking mechanisms.

 You need to make sure no mechanisms are locked (registers, door, air inlet, etc.) after an extended 

shutdown period. 

5.1.2. Spare parts. 

Use only original spare parts, or parts recommended by Manufacturas Rocal, S.A. See picture on section “V” of 

the ANNEXED document. 

5.2. Cleaning.

 It is important for the appliance to be clean of ash so that all mechanisms work properly. To clean the body of the 

device 

use the cleaning dry cloth given with the appliance or similar. Do not use current cleaning products

.

 

5.2.1 Glass. 

You must turn the device off to clean the glass. The products used must not come into contact with the metal parts of 

the door or the ceramic board; the aggressiveness of these products can cause a corrosion process of the equipment. To replace the 

glass follow the steps described in the "D.2” image on the ANNEXED document. 

 

5.2.2 Ash box. 

Empty the box only when the appliance is completely turned off,

 ensuring that the ashes do not contain any 

burning coals

; in which case you should deposit them in a metal bucket. To access the ash basin follow the steps shown in pictures 

“D.4”, and “D.5” of the ANNEXED document. 

IMPORTANT:   -The interior vermiculite parts SHOULD NOT RECEIVE IMPACTS when refueling is 

performed.  

If any of these parts crack, but is properly set in its place, THE PROPER OPERATION OF 
THE APPLIANCE SHALL NOT BE ALTERED AND THERE IS NO POTENTIAL RISK. The 
equipment can be used normally. These cracks do not entail any manufacturing defect so 
they do not fall under guarantee 

 

5. CLEANING AND MAINTENANCE 

CAUTION: 

- The maximum load allowed by the manufacturer, the measurements of the logs and the 
height of the reload must be respected. 

- Do not touch or manipulate any part of the appliance when in operation without a 
protection glove.

 

Summary of Contents for G 450 DC

Page 1: ...58618380 Serie G G 450 DC MANUAL DE CARACTERISTICAS INSTALACION Y FUNCIONAMIENTO USER S GUIDE ON CHARACTERISTICS ASSEMBLY AND OPERATING MANUEL DES CARACTERISTIQUES INSTALLATION ET FONCTIONNEMENT MANU...

Page 2: ...your purchase L quipe de Rocal vous remercie pour votre confiance en nous et pour choisir un de nos produits Profitez de votre achat Il team di Rocal La ringrazia per la fiducia accordataci e per aver...

Page 3: ...mbusti n 5 4 3 1 Registro primario 5 4 3 2 Registro secundario 5 4 4 Encendido 5 4 5 Carga y recarga de combustible 5 4 6 Apertura de la puerta 5 4 7 Funcionamiento en condiciones climatol gicas adver...

Page 4: ...ciente capacidad portante para soportar el peso De no ser as debe realizarse una placa de reparto de la carga para una distribuci n equitativa del peso del aparato En caso de duda consulte a un especi...

Page 5: ...e debe rever la colocaci n de difusores de ventilaci n en el nicho de hogar tanto para la entrada como para la salida V ase la secci n m nima que se recomienda es de 450 cm2 En su interior no debe con...

Page 6: ...eriales sometidos a cambios de temperatura sufren dilataciones Este fen meno puede ocasionar ruidos met licos espor dicos o con m s o menos frecuencia Estos son completamente inocuos y no suponen ning...

Page 7: ...r dichos elementos A continuaci n se muestra algunos de los elementos Elemento C digo Descripci n ECOntrol C7000 Regulador inteligente de la combusti n Regulador REGULAT 1 Regulador de velocidad de la...

Page 8: ...tible inadecuado Carga insuficiente Registros del control de la combusti n en una posici n incorrecta Utilizar combustible recomendado A adir combustible Ajustar los registros 5 Salida de humos y o ga...

Page 9: ...con su distribuidor Rocal ENGLISH INDEX 1 SPECIFICATIONS 9 1 1 Technical specifications 9 1 2 Breakdown of delivery components 10 ATENCI N Todas las pruebas han sido realizadas siguiendo la Normativa...

Page 10: ...12 4 3 2 Secondary register 12 4 4 Fire lighting 12 4 5 Loading and reloading of fuel 12 4 6 Door opening 12 4 7 Operation in adverse weather conditions 12 4 8 Fire Prevention 12 4 9 Dilations of the...

Page 11: ...ng plate for the equitable distribution of the equipment s weight In case of doubt please consult a specialist Parameter Modelo G 450 DC Minimum Maximum draught Pa 11 13 Fuel consumption kg h 4 05 Smo...

Page 12: ...nt frame Inside should not contain flammable or fragile materials such as wood wallpaper glass chalk paper etc 2 7 Ventilation It is imperative that the niche where the appliance is installed ventilat...

Page 13: ...dren and elderly people present In case of fire push away all the people around it close the registers as much as possible and notify the Firefighting service 4 9 Dilations of the sheet Materials subj...

Page 14: ...nd or salinity in the environment seawater it is in contact with chemical cleaning products or with water inputs through the duct etc Use exclusively Rocal heatproof spray paint Rocal offers various o...

Page 15: ...oor heating Inappropriate fuel Insufficient load Combustion control registers in the wrong position Use recommended fuel Adding fuel Adjust registers 5 Venting smoke and or gases from the front bad sm...

Page 16: ...lations UNE EN13240 2002 A2 2005 AC 2006 A2 2005 AC 2007 Stoves that use solid fuels Requirements and test methods The review of the equipment the installation and ducts must be carried out by a profe...

Page 17: ...1 Registre primaire 19 4 3 2 Registre secondaire 19 4 4 Allumage 19 5 ENTRETIEN ET NETTOYAGE 19 4 5 Chargement et rechargement de combustible 19 4 6 Ouverture de la porte 19 4 7 Fonctionnement dans d...

Page 18: ...n est pas le cas une plaque de r partition des charges doit tre install e afin que le poids de l appareil se distribue de mani re homog ne En cas de doute consultez un sp cialiste Parameter Modelo G...

Page 19: ...t A l int rieur ne doit pas contenir des mat riaux inflammables ou fragiles tels que le bois le papier peint verre papier de craie etc 2 7 Ventilation Il est imp ratif que la niche o l appareil est in...

Page 20: ...sses de pression ou le retour des courants d air l int rieur du conduit de fum es Lorsque ces ph nom nes sont observ s il est pr f rable de fermer les registres d air de la combustion et laisser le fe...

Page 21: ...reil la chambre de combustion l int rieur la partie frontale les joint c ramiques elle r siste une chaleur maximale de 600 C et elle d gage une l g re odeur caract ristique qui dispara t avec les prem...

Page 22: ...mbustible en vitant une temp rature trop lev e R gler les r euille egistres 4 Chauffage insuffisant Combustible inappropri Chargement insuffisant Registres de contr le de la combustion dans une positi...

Page 23: ...CHE 23 1 1 Specifiche tecniche 23 1 2 Dettaglio dei componenti di consegna 24 ATTENTION Tous les essais ont t r alis s conform ment la Norme UNE EN 13229 2002 UNE EN 13229 2002 A2 2005 UNE EN 13229 20...

Page 24: ...gistro secondario 26 4 4 Accensione 26 4 5 Carica e ricarica di combustibile 26 4 6 Apertura de la puerta 26 4 7 Funzionamento in condizioni climatiche avverse 26 4 8 Prevenzione incendio 26 4 9 Dilat...

Page 25: ...l impianto In caso di dubbio consultate uno specialista 2 2 Condotta di uscita fumi obbligatorio un connettore dei fumi con sistema stagno dal collegamento del tubo dell impianto fino all esterno e de...

Page 26: ...to di diffusori di ventilazione nella nicchia del focolare di entrata e di uscita Vedi la sezione minima consigliata nella tabella 1 1 Caratteristiche tecniche Tabla orientativa de ventilaci n difusor...

Page 27: ...a rumori metallici sporadici pi o meno frequenti Si tratta di rumori completamente innocui che non comportano alcun rischio n problema di funzionamento 5 1 Manutenzione Una manutenzione adeguata e ri...

Page 28: ...l contatto con detergenti chimici o al contatto con acqua entrate attraverso il tubo ecc Usate solo l aerosol Rocal pintura antical rica vernice anticalorica Rocal offre diversi elementi opzionali con...

Page 29: ...egolare i registri 4 Riscalda poco Combustibile inadeguato Carico insufficiente Registri di controllo della combustione in una posizione incorretta Utilizar combustible recomendado A adir combustible...

Page 30: ...endo la Normativa UNE EN 13229 2002 UNE EN 13229 2002 A2 2005 UNE EN 13229 2002 AC 2006 UNE EN 13229 2002 A2 2005 AC 2007 Siano i controlli dell impianto che l installazione e le condotte devono esser...

Page 31: ...2 4 3 1 Registro prim rio 33 4 3 2 Registro secundario 33 4 4 Igni o 33 5 MANUTEN O E LIMPEZA 33 4 5 Carga y recarga de combustible 33 4 6 Apertura de la puerta 33 4 7 Opera o em condi es clim ticas a...

Page 32: ...RESPONSABILIDADE Parameter Modelo G 450 DC Tiragem m nima m xima Pa 11 13 Consumo kg h 4 05 Tiragem de fumos g s 15 24 Rendimiento 82 Potenza termica kW 14 8 Intervalli di potenza kW 10 17 5 A concen...

Page 33: ...t instalado de ventila o dispon veis 2 7 1 Ventilaci n del nicho de hogar Deve prever a coloca o de sa das de ar no nicho para que a entrada e a sa da de fluxo de ar seja suficiente conforme descrito...

Page 34: ...condutas e de instala o Assim para sua seguran a e conforto alguns dos nossos distribuidores oferecem manuten o contrato Contacte o seu revendedor para este servi o 5 1 1 Bloqueio de mecanismos Voc p...

Page 35: ...a o para a combust o Posi o incorreta de registros Sujeira do duto Verifique tubula o Conex o Di metro Vazamentos em seu caminho Comprimento insuficiente Chamadas de sa da Poss veis elementos que obst...

Page 36: ...incorrecto verificar a veda o da porta A etiqueta de marca o CE est localizada no interior da porta de carga Esta tag cont m os dados t cnicos eo N OF este n mero tambi n lo encontrar en la hoja de ga...

Page 37: ...300 mm CO concentration at 13 of O2 0 12 Thermal power 14 8 kW Performance 82 NOx 91 11 mg Nm3 OGc 71 88 mg Nm3 Particle concentration 29 47 mg Nm3 Temperature of smoke 189 C Fuel Natural Wood NB 0370...

Page 38: ...1 ANEXO ANNEX ANNEXE ANESSO I...

Page 39: ...2 II 1 10 11 9 4 2 5 3 6 7 8 13 12...

Page 40: ...3 III 1 2...

Page 41: ...4 III 1 2 3 4 5 6...

Page 42: ...5 III 7 8 8 A 1 A 2 A 3...

Page 43: ...6 III A 5 B 1 B 2 B 3 B 4 B 5...

Page 44: ...7 III B 6 B 7 B 8 C 1 C 2...

Page 45: ...8 IV D 1 D 2 D 3 D 4 D 5 D 6...

Page 46: ...9 IV D 7 D 8 D 9 D 10 D 11 D 12...

Page 47: ...10 D 13...

Page 48: ...5 2019 M1840 200 M1841 88A VRM1841 2 VRM1841 1 VRM1841 1 VRM1841 2 CERAMC5 CERAMC6 M1841 200 CERAMC8 M1841 72 73 M1841 67 68 69 M1840 300 CERAMC6 CERAMC5 VRM1841 1 VRM1841 1 CERAMC6 M1841 300 VRM1841...

Reviews: