8
1.1 Technical specifications
* Values obtained in the laboratory of Manufacturas Rocal
1.2 Breakdown of delivery components
(Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1.
Fireplace’s body.
2.
Heat-resistant spray paint for touch-ups.
3.
Heat-resistant glove.
4.
Cleaning cloth
5.
Outdoor air intake Kit. (Outdoor air intake connector, support for the connector, tubular seal and screws)
6.
Tool for handling registers and opening door.
7.
Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.
8.
Outlet hot air connector
9.
Bag with screws
10.
+ Plus 180 (ARc 80 DC +Plus 180, ARc 100 DC +Plus 180)
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I, page 1.
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH UPON
INSTALLATION OF THE EQUIPMENT.
Parameter
Model
ARc 80 DC*
ARc 80 DC
+Plus 180
ARc 100 DC*
ARc 100 DC
+Plus 180
Minimum - Maximum draught
11-13 Pa
11-13 Pa
11-13 Pa
11-13 Pa
Fuel consumption
3,7
3,35 kg/h
4 kg/h
4 kg/h
Smoke mass flow rate
16,3 g/s
14,3 g/s
17,5 g/s
19,5 g/s
Efficiency
≥
70 %
85,7 %
≥
68 %
75,9%
Nominal output
11,5 kW
12,4 kW
13 kW
13,4 kW
Power range
8 – 14 kW
8,5 – 14,5 kW
9,5 - 15 kW
9 – 15 kW
Average CO concentration at 13% of O2
≤
0,18 %
0,107 %
≤
0,20 %
0,10 %
NOx concentration at 13% of O2
*
***
108 mg/Nm
3
****
102 mg/Nm
3
OGC concentration at 13% of O2
*
***
141 mg/Nm
3
****
81 mg/Nm
3
Particle concentration at 13% of O2
*
***
34 mg/Nm
3
****
16,30 mg/Nm
3
Medium draft (trial)
12 Pa
12,5 Pa
12 Pa
13,3
Net weight
160 kg
177,9 kg
216 kg
223,9 kg
Maximum authorized load (fuel)
4 kg
4 kg
5 kg
5 kg
Reload height
200 mm
200 mm
200 mm
200 mm
Logs length
400 mm
400 mm
500 mm
500 mm
Minimum flue height
4000 mm
4000 mm
4000 mm
4000 mm
Ø Flue duct
180 mm
180 mm
180 mm
180 mm
Ø Air inlet
100 mm
100 mm
100 mm
100 mm
Ø Air outlet
120 mm
120 mm
120 mm
120 mm
Inner fireplace room safety distances (back)
1000 mm
1000 mm
1000 mm
1000 mm
Inner fireplace safety distances (sides)
50 mm
50 mm
50 mm
50 mm
Outer fireplace safety distances (back)
1000 mm
1000 mm
1000 mm
1000 mm
Outer fireplace safety distances (sides)
750 mm
750 mm
750 mm
750 mm
Outer fireplace safety distances (frontal)
1000 mm
1000 mm
1000 mm
1000 mm
Fireplace room ventilation (entry - exit)
450 cm
2
450 cm
2
450 cm
2
450 cm
2
Minimum safety distance to the air outlets
250 mm
Average temperature of smoke
225,4 ºC
138,8 ºC
222,8 ºC
217 ºC
Type of combustion
INTERMITENT
Flue liner
NOT SHARED
Fuel
NATURAL WOOD
Humidity fuel logs
12-20 % - 2 YEARS UNDER COVER
Certification year
*
***
2019
****
2019
Certificate number
****
1800-CPR-020-19
****
1800-CPR-038-19
1. SPECIFICATIONS
2. REQUIREMENTS PRIOR TO INSTALLATION
Summary of Contents for ARc DC 100
Page 34: ...33 II 1 2 3 4 5 6 7 8 9 10 ...
Page 35: ...34 III 1 2 ...
Page 36: ...35 III 1 2 3 A B A 1 ...
Page 37: ...36 III A 2 A 3 A 4 A 5 B 1 B 2 ...
Page 38: ...37 III B 3 Plus 180 B 3 B 4 B 5 ...
Page 39: ...38 IV D 1 D 2 D 3 D 4 D 5 D 6 ...
Page 40: ...39 IV D 7 D 8 D 9 D 10 D 11 D 12 ...
Page 41: ...40 III IV D 13 D 14 D 15 D 16 D 17 D 18 ...
Page 42: ...41 IV D 19 D 20 D 21 D 22 D 23 D 25 ...
Page 44: ...43 ...