Installation, Operation and Maintenance Manual– Ed.07/2005
7
EVOLUZIONE series natural gas/LPG heaters
2 FOR THE USER
2.1 SWITCHING THE APPLIANCE ON AND OFF
The first switching on of the appliance must be carried out by
professionally qualified personnel.
Before starting the heater, have professionally qualified personnel check that:
•
the data on the plate correspond to the data from the electricity and gas supply grids
•
the calibration is compatible with the power of the heater
•
the exhaust gas pipe is operating correctly
•
the intake of combustion air and outlet of exhaust gases occur correctly in accordance with the
specifications of current legislation
WINTER
1. Set the index of the ambient thermostat to maximum.
2. Check that the gas valve is open.
3. Supply current to the appliance by closing the omnipolar switch (provided by the electrical installation
technician).
4. Set the summer/winter switch to the winter position (indicated by the snowflake symbol ).
5. After a pre-wash time of approximately 30 seconds, the gas electrovalve opens and the burner switches
on.
6. When a flame is present, the central control unit keeps the gas valve open.
7. If no flame is present, the central control unit arrests operation of the appliance, and the arrest light
illuminates on the reset button.
8. If point 7 applies, press the reset button.
9. If ignition is trouble-free, set the ambient thermostat index (not supplied as standard) to the value desired.
If the appliance is switched on after a long period of disuse, or the first time the appliance is switched on, it
may be necessary to repeat the operation several times, due to air being present in the gas pipes.
SWITCHING OFF
To switch off the appliance, set the ambient thermostat index to the minimum. The burner will switch off, while
the fans will continue to operate until the appliance has fully cooled.
If the appliance is not used for a protracted period, after the operation described above and after waiting for
the fans to cease operating, close the gas valve and cut off electrical current to the appliance via the
omnipolar switch located on the power supply line.
In no circumstances must the appliance be switched off by removing the power supply from it directly. This
can damage the appliance, as it causes the fans to stop immediately and the limit thermostat to be activated,
which must be reset manually.
WARNING
WARNING
WARNING
WARNING