The electrical safety of the appliance is guaranteed only when it is correctly connec-
ted to an efficient grounding system, executed in accordance with current safety
regulations.
Installation and regulatory references
When the appliance arrives at the installation site, before beginning the stages requi-
red to move it in order to position it on the site, perform a visual check to ascertain that
there are no evident signs of breakage or damage to the packaging or to the external
panels, which would be signs that damage occurred during transport.
Packing materials must be removed only after the appliance has been positioned on
site. After removing the packing materials, ensure that the appliance is intact and
complete.
Installation of the appliance may only be carried out by firms that are qualified in ac-
cordance with current legislation in the country of installation, i.e. by professionally
qualified personnel.
"Professionally qualified personnel" means personnel with specific technical compe-
tence in the sector of heating/cooling plants and gas appliances.
Installation of the appliance must be carried out in compliance with current local and
national regulations regarding the design, installation and maintenance of heating
and cooling plants in accordance with the manufacturer's instructions.
In particular, current regulations regarding the following must be observed:
Gas equipment.
•
Electrical equipment.
•
Heating systems employing condensation boilers.
•
Every other standard and regulation that concerns the installation of equipment
•
for summer and winter air conditioning using gas fuel.
The manufacturer does not accept any contractual or extra-contractual liability for any
damage caused by errors in installation and/or failure to observe the abovementioned
regulations and the instructions supplied by the manufacturer itself.
Once the appliance is installed
The firm that has undertaken the installation must provide the owner with a declara-
tion that the installation has been carried out in compliance with proper workmanship
practices, current national and local regulations, and the instructions supplied by Ro-
bur S.p.A.
Before contacting your authorised Robur Technical Assistance Centre (TAC) for the
ini-
tial activation
, the firm must ensure that:
the electricity and gas mains specifications correspond to the specifications on
•
the
nameplate
;
the mains gas pressure falls within the range of values specified in Table
•
4.1
→
31;
the gas supplied to the appliance is of the type for which it is designed;
•
the gas supply system and water distribution system are sealed;
•
the gas and electricity supply systems are correctly rated for the capacity re-
•
quired by the appliance and that they are equipped with all safety and control
devices prescribed by current regulations
Check that no safety and control devices are excluded, by-passed or not working
correctly.