Address
Size
(Byte)
Data Name
Access Default
Value
Range
Unit
251
1
RW
0
0 ~ 255
-
578
2
RW
634
64 ~ 661
-
580
2
RW
635
64 ~ 661
-
582
2
RW
636
64 ~ 661
-
…
…
…
…
…
-
-
628
2
RW
659
64 ~ 661
-
630
2
RW
660
64 ~ 661
-
632
2
RW
661
64 ~ 661
-
634
1
RW
0
0 ~ 255
-
635
1
RW
0
0 ~ 255
-
636
1
RW
0
0 ~ 255
-
…
…
…
…
…
-
-
659
1
RW
0
0 ~ 255
-
660
1
RW
0
0 ~ 255
-
661
1
RW
0
0 ~ 255
-
CAUTION
: Protocol 1.0 does not support addresses greater than 256. Therefore, Indirect Address 29 ~
56 and Indirect Data 29 ~ 56 can only be accessed with Protocol 2.0.
2. 4. Control Table Description
CAUTION
: Data in the EEPROM Area can only be written when the value of Torque Enable(64) is
cleared to ‘0’.
This address stores model number of DYNAMIXEL.
This address stores firmware version of DYNAMIXEL.
The ID is a unique value in the network to identify each DYNAMIXEL with an Instruction
Packet. 0~252 (0xFC) values can be used as an ID, and 254(0xFE) is occupied as a broadcast
ID. The Broadcast ID(254, 0xFE) can send an Instruction Packet to all connected DYNAMIXEL
simultaneously.