Robotiq Finishing Kits- Instruction Manual
Caution
For more details on minimum/maximum operating temperatures, please refer to the Environmental and Operating
Caution
The recommended threshold represents the smallest variations that can be detected by the sensor.
The signal noise is the limiting factor for the Sensor's precision. For the FT 300-S, the signal noise defined in the signal
specifications is the standard deviation of each data (Fx, Fy, Fz, Mx, My, Mz) over 1 second. In order to use that signal noise
information, three times the standard deviation given must be used. According to the normal distribution, three times the
standard deviation will cover almost all values possible (99.7%).
Info
Noise is an unwanted and unpredictable alteration to a signal. It may come from electrical or electromagnetic sources
and degrades the quality of the Sensor's signal.
5.6. Electrical Ratings
SPECIFICATION
VALUE
Input voltage
5 to 24 V DC ± 10%
Max power consumption
2 W
Communication electrical interface
RS-485
Recommended fuse
Phoenix #0916604 (UT6-TMC M 1 A)
Recommended power supply
TDK-Lambda DPP Series
15W Single Output DIN Rail Mount Power Supply
,
DPP15-24
86