13
20/03/2018
4° USING THE VACUUM KIT R-VAC
®
- Connect up the vacuum pump to valve
A
, check that the
latter is open (lever in shaft of connector).
- Shut valve
B
(perpendicular lever).
1° ASSEMBLING THE VACUUM KIT R-VAC
®
- Insert filter
N° 2
into body
N° 3
- Screw part
N° 1
onto body
N° 3
(the tube is fed through body
N° 3
).
2° PLACING THE VACUUM KIT R-VAC
®
ON THE LID
- Insert the vacuum kit into the cone section of the plastic
part
N° 5.
The latter should be screwed into the lid guide
N° 6
which, in turn, should be slotted into the aluminium
lid arm
N° 8
. The lid
N° 9
should also be clipped onto the
lid guide
N° 6
.
5° ADDING LIQUID TO THE MIXTURE
- Attach a tube to valve
B
.
- Immerse the other end of this tube in the liquid to be added.
- Open valve B slowly ; once the liquid has been added, shut valve B.
3° CLIPPING THE
RETAINER
N° 4
- Hold the bell in the palm of your hand and press the pusher
N° 7
in with your thumb.
- Fit the nut onto the cylindrical section which juts out over
the lid.
- Release button
N° 7
.
- The pusher should return to its original position. If it does not,
press the bell gently so that it automatically clicks into place.
- Check that the bell is properly attached to the tube
N° 1
, in
order to avoid all risk of the bell or kit falling off.
OPERATING INSTRUCTIONS FOR THE VACUUM KIT R-VAC
®
(Cutter only)
Keep an eye on the position
of the O-ring seal when fitting
part
N° 1.
Filter
N° 2
can
be cleaned.
Check that the openings are in
the upper position in order to
position nut
N° 4.
7
9
4
5
8
6
N O T E
Preheat the vacuum pump (approx. 15 minutes) to check that both it and the
vacuum kit are working properly. Similarly, leave the pump running for 15
minutes after completing the task in order to evacuate the condensation.