background image

 

        

 

 

 
 

Contact

 

Details

 

 

Please

 

note

 

that

 

some

 

of

 

the

 

contact

 

details

 

on

 

this

 

PDF

 

document

 

may

 

not

 

be

 

current.

 

 

Please

 

use

 

the

 

following

 

details

 

if

 

you

 

need

 

to

 

contact

 

us:

 

 

Telephone:

 

0844

 

879

 

3588

 

Email:

 

[email protected]

 

 
 

The

 

Help

 

Centre

 

section

 

of

 

this

 

website

 

also

 

features

 

a

 

wide

 

range

 

of

 

information

 

which

 

may

 

be

 

of

 

use

 

to

 

you

 

and

 

is

 

available

 

24

 

hours

 

a

 

day.

 

It

 

includes:

 

 

 

Manuals

 

and

 

guides

 

downloads

 

 

Servicing

 

 

Where

 

to

 

buy

 

our

 

products

 

 

Literature

 

downloads

 

 

www.robinsonwilley.co.uk/help

 

A division of GDC Group Ltd 
Millbrook House   Grange Drive   Hedge End   Southampton   SO30 2DF 
www.robinsonwilley.co.uk

 

Registered No: 1313016 England

VAT GB 287 1315 50004 

EEE Producer Registration Number – 

WEE/GE0057TS 

Paper from sustainable sources 

Summary of Contents for Bantam Ecotherm LPG

Page 1: ...features a wide range of information which may be of use to you and is available 24 hours a day It includes Manuals and guides downloads Servicing Where to buy our products Literature downloads www r...

Page 2: ...1 Instructions for Installation and Servicing FOR USE IN G B I E CAT I G20 at 20mbar 2H CAT I G30 31 at 28 37mbar 3 Warmplan XX Series AUTO G C No 35 694 56 MANUAL G C No 35 694 57...

Page 3: ...clock and thermostat an electronic system controls the heater automatically Warmplan XX G C No 35 694 57 This heater is identical to the Warmplan XX Auto except that it is not fitted with a time clock...

Page 4: ...urtains should clear the heater by 25mm 4 Ensure that there is an adequate gas supply available 5 Ensure that there is a suitable electrical supply available 6 If the heater is to be fitted with a flu...

Page 5: ...ith a piece of sealing tape Long FX3 Suitable for walls from 355mm 14 to 510mm 20 Medium FX2 205mm 8 to 355mm 14 Short FX1 125mm 5 to 205mm 8 Flues of lengths above 510mm 20 and up to 1525mm 60 are al...

Page 6: ...n the wall and that the rubber sealing ring is in place immediately behind the air intake flange Do not render over the face of the rubber sealing ring should rendering be necessary 6 If the flue term...

Page 7: ...ne end is already attached to the heater and has a mains cable clamp fitted Slacken the nut on the cable clamp slide it in the slot in the support plate at the bottom right hand side of the backplate...

Page 8: ...appliance electrically disconnected all switches ON including stats a meter set on W Ohms x 1 scale Test leads from L to N in appliance terminal strip block if meter reads 0 then there is a short cir...

Page 9: ...ntrol knob clockwise to position 6 The amber lamp will come on indicating that the ignition cycle has started After about 20 seconds the red lamp will come on The heater is now operating Check that th...

Page 10: ...intain the selected heat level 4 The gas cock below the heater should be left ON even when the heater is not in use 5 Neither clothes nor material should be draped over the louvres nor should furnitur...

Page 11: ...L BLUE When the flame is detected convection fan starts and red light comes on as well YL YELLOW BR BROWN Overheat limit switch operates Red light goes out Amber light stays on Gas fails lock out Red...

Page 12: ...E BL BLUE When the flame is detected convection fan starts and red light comes on as well YL YELLOW BR BROWN Overheat limit switch operates Red light goes out Amber light stays on Gas fails lock out R...

Page 13: ...12 WARMPLAN AUTO FUNCTIONAL FLOW...

Page 14: ...13 WARMPLAN MANUAL FUNCTIONAL FLOW...

Page 15: ...case 1 Turn off gas and electrical supplies 2 Remove the two screws located at the bottom of the dressing strip and slacken the two screws located behind the top louvre Fig 1 Pull the case away from...

Page 16: ...taining clips using pliers or similar and release the capillary tube and phial 4 Remove the nut and washer on the thermostat spindle and pull the thermostat assembly from the control bracket 5 Fit the...

Page 17: ...not damaged Re fit the screws and washers 6 Remake the electrical connections 7 To clean the fan brush the rotor blades with a soft brush until all the dust is removed The fan does not need lubricatin...

Page 18: ...t To assist re assembly the gasket may be held in position with a few spots of contact adhesive Replace the screws and washers and remake the gas connection Replace the air guide then replace the elec...

Page 19: ...il the electrical supply is broken and re made by turning the control knob to the OFF position or operating the override switch 2 If while the heater is running normally the flame fails because of Com...

Page 20: ...ctrode Assembly including Key No 40 Gasket Electrode Solenoid Valve Gasket Injector Holder Pressure Test Nipple Screw Printed Circuit Board Electrode 389 283 389 282 203 796 203 797 393 344 203 798 39...

Page 21: ...y Bentleywood Way Network 65 Business Park Hapton Burnley BB11 5ST Telephone 01282 686791 Fax 01282 686799 E mail info robinsonwilley co uk website www robinsonwilley co uk Robinson Willey is a Tradin...