Robinson Willey Bantam Ecotherm LPG User Manual Download Page 17

16

3. 

Fit the new fan over the bosses on the back plate; fit the spacing collar and replace the screws and 
washers. Make sure that the air guide on the fan fits behind the front division sheet. 

Remake the electrical connections. 

5. 

To clean the fan, brush the blades with a soft brush until all the dust is removed. The fan does not 
need lubricating. 

Combustion Fan 

1.

Remove the front division sheet by removing four screws. 

2.

Disconnect the fan wires from the main terminal block and the earth connection from the fan. 

3. 

Remove the two screws and washers holding the fan to the heat exchanger and pull off the fan and its 
rubber connecting duct. 

4. 

Fit the rubber duct to the new fan. Always fit a new gasket when the fan has been removed. For ease 
of  assembly,  the  new  gasket  may  be  secured  to  the  flange  of  the  fan  with  a  few  spots  of  contact 
adhesive. 

5. 

Fit the fan to the heat exchanger, making sure that the rubber duct fits securely round the plunged 
hole in the backplate and that the sealing gasket is not damaged. Re-fit the screws and washers. 

6. 

Remake the electrical connections 

7.

To clean the fan, brush the rotor blades with a soft brush until all the dust is removed. The fan does 
not need lubricating. 

Solenoid Valves 

1.

Pull off tag connector from the spark electrode. Remove two screws and washers from the air guide 
and remove the air guide. 

2.

Disconnect the gas inlet connection to the heater. 

3.

Remove the six wire connectors to the solenoid valve assembly (Note their positions). 

4.

Disconnect the tubing nut connection on the burner supply pipe. 

5. 

Remove  the  two  screws  and  washers  fixing  the  burner  supply  tube  to  the  burner  mounting  plate. 
Remove the valve assembly and burner supply tube out from the valve support bracket and away 
from the heater. 

6. 

Fit the new valve assembly to the heater using the new gasket provided. 

7.

Resecure the valve assembly using the existing screws and washers. Tighten the inlet gas connection 
and the tubing nut. 

8.

Refit the six wire connections, Their positions can be seen on the wiring diagram provided in these 
instructions. 

9.

Refit the air guide and reconnect the spark lead to its electrode (the one with the round pin). 

10.

Reconnect the gas and electrical supplies. 

Summary of Contents for Bantam Ecotherm LPG

Page 1: ...features a wide range of information which may be of use to you and is available 24 hours a day It includes Manuals and guides downloads Servicing Where to buy our products Literature downloads www r...

Page 2: ...1 Instructions for Installation and Servicing FOR USE IN G B I E CAT I G20 at 20mbar 2H CAT I G30 31 at 28 37mbar 3 Warmplan XX Series AUTO G C No 35 694 56 MANUAL G C No 35 694 57...

Page 3: ...clock and thermostat an electronic system controls the heater automatically Warmplan XX G C No 35 694 57 This heater is identical to the Warmplan XX Auto except that it is not fitted with a time clock...

Page 4: ...urtains should clear the heater by 25mm 4 Ensure that there is an adequate gas supply available 5 Ensure that there is a suitable electrical supply available 6 If the heater is to be fitted with a flu...

Page 5: ...ith a piece of sealing tape Long FX3 Suitable for walls from 355mm 14 to 510mm 20 Medium FX2 205mm 8 to 355mm 14 Short FX1 125mm 5 to 205mm 8 Flues of lengths above 510mm 20 and up to 1525mm 60 are al...

Page 6: ...n the wall and that the rubber sealing ring is in place immediately behind the air intake flange Do not render over the face of the rubber sealing ring should rendering be necessary 6 If the flue term...

Page 7: ...ne end is already attached to the heater and has a mains cable clamp fitted Slacken the nut on the cable clamp slide it in the slot in the support plate at the bottom right hand side of the backplate...

Page 8: ...appliance electrically disconnected all switches ON including stats a meter set on W Ohms x 1 scale Test leads from L to N in appliance terminal strip block if meter reads 0 then there is a short cir...

Page 9: ...ntrol knob clockwise to position 6 The amber lamp will come on indicating that the ignition cycle has started After about 20 seconds the red lamp will come on The heater is now operating Check that th...

Page 10: ...intain the selected heat level 4 The gas cock below the heater should be left ON even when the heater is not in use 5 Neither clothes nor material should be draped over the louvres nor should furnitur...

Page 11: ...L BLUE When the flame is detected convection fan starts and red light comes on as well YL YELLOW BR BROWN Overheat limit switch operates Red light goes out Amber light stays on Gas fails lock out Red...

Page 12: ...E BL BLUE When the flame is detected convection fan starts and red light comes on as well YL YELLOW BR BROWN Overheat limit switch operates Red light goes out Amber light stays on Gas fails lock out R...

Page 13: ...12 WARMPLAN AUTO FUNCTIONAL FLOW...

Page 14: ...13 WARMPLAN MANUAL FUNCTIONAL FLOW...

Page 15: ...case 1 Turn off gas and electrical supplies 2 Remove the two screws located at the bottom of the dressing strip and slacken the two screws located behind the top louvre Fig 1 Pull the case away from...

Page 16: ...taining clips using pliers or similar and release the capillary tube and phial 4 Remove the nut and washer on the thermostat spindle and pull the thermostat assembly from the control bracket 5 Fit the...

Page 17: ...not damaged Re fit the screws and washers 6 Remake the electrical connections 7 To clean the fan brush the rotor blades with a soft brush until all the dust is removed The fan does not need lubricatin...

Page 18: ...t To assist re assembly the gasket may be held in position with a few spots of contact adhesive Replace the screws and washers and remake the gas connection Replace the air guide then replace the elec...

Page 19: ...il the electrical supply is broken and re made by turning the control knob to the OFF position or operating the override switch 2 If while the heater is running normally the flame fails because of Com...

Page 20: ...ctrode Assembly including Key No 40 Gasket Electrode Solenoid Valve Gasket Injector Holder Pressure Test Nipple Screw Printed Circuit Board Electrode 389 283 389 282 203 796 203 797 393 344 203 798 39...

Page 21: ...y Bentleywood Way Network 65 Business Park Hapton Burnley BB11 5ST Telephone 01282 686791 Fax 01282 686799 E mail info robinsonwilley co uk website www robinsonwilley co uk Robinson Willey is a Tradin...

Reviews: