Installation -
continued
Technical information (continued)
Connecting the mains supply cable
The mains terminal block is located on the underside of the cooktop and the terminals are accessible by removing the
terminal block cover by removing the cover screw.
The cable connections must be in accordance with the diagram located on the bottom of the cooktop.
The brass links must be positioned as marked in the appropriate diagram and once established ALL terminal screws must
be tightened down firmly.
If when the cooktop is first switched on, only two of the zones work, you should recheck that the terminal screws
are all fully tightened between the links.
IMPORTANT:
The appliance must NOT be connected to the mains supply by means of a 15A plug and socket.
The cable can be looped if necessary, but make sure that is not kinked or trapped when the cooktop is in position. Care
must be taken to avoid the cable being in contact with hot parts of the appliance.
Replacing the mains supply cable
If the mains supply cable is damaged, then it must be replaced by an appropriate replacement which can be obtained
from the Seller. The mains supply cable should be replaced in accordance with the following instructions:
•
Switch the appliance off at the control switch.
•
Open the terminal block on the underside of the cooktop.
•
Unscrew the terminal screws fixing the cable.
•
Replace the cable with one of the same length and in accordance
•
with the specification given above.
•
The “green-yellow” earth wire must be connected to the terminal marked . It must be about 10 mm longer than the
live and neutral wires.
•
The “blue” neutral wire must be connected to the terminal marked with letter (N) - the live wire must be connected
to the terminal marked with letter (L).
6