31
−
−
* Checking table for analogue circuit tester.
Analogue circuit tester
Apply black - needle of the circuit tester
Yellow
Black
1
1
White
2
2
Light green
3
3
Brown
4
4
orYellow
Apply red +
needle of
the circuit
tester
Yellow
---------------
∞
∞
∞
∞
Black
1
1
∞
---------------
200 k
Ω
∞
300 k
Ω
White
2
2
∞
60 k
Ω
---------------
∞
100 k
Ω
Light green
3
3
16 k
Ω
350 k
Ω
125 k
Ω
---------------
14 k
Ω
Brown
4
4
orYellow
∞
250 k
Ω
100 k
Ω
∞
---------------
8-9 CURRENT TRANSFORMER
(RGV13100T only)
Disconnect the connectors and couplers of
current transformer.
Check the inter-terminal resistance of current
transformer with a circuit tester.
If current transformer is found to be faulty, replace with new one.
8-10 ECU (ELECTRONIC CONTROL UNIT)
Check the resistance between 13 terminals
of ECU with circuit tester.
Terminal number of the ELECTRONIC CON-
TROL UNIT
10
13
7
1
11
3
6
8
12
2
5
9
4
Terminal number
1 and 2
1 and 3
RGV13100T
2.00
Ω
2.00
Ω
0.009
Ω
2 and 3