My energy bills are too high. Is there anything I can do?

While we can’t do anything about the high cost of energy, we can try to use less energy and thereby lower our heating and
cooling costs.

Generally, the best way to do this is to use the EPA E

NERGY

S

TAR®

recommended setpoints for heating and cooling.

E

NERGY

S

TAR®

Setpoints

Winter

Summer

(Heating)

(Cooling)

Morning

70°F (21°C)

78°F (25°C)

Day

62°F (17°C)

85°F (29°C)

Evening

70°F (21°C)

78°F (25°C)

Night

62°F (17°C)

82°F (28°C)

Another way to contain costs is to cycle the heat pump or air conditioner with moderation. The thermostat controls the cycle rate
based on temperature differentials. By maintaining a reasonable differential setpoint, 1°F for 1st stage and 2°F for 2nd stage,
your furnace will cycle with moderation.

Finally, using the remote outdoor sensor coupled with the balance point feature (see INSTALLER SETTINGS, page 20) will
allow your furnace to cycle to the most efficient stage for your heating or cooling needs. 

110-1023E.qxd  11/18/04  10:50 AM  Page 25

Summary of Contents for 9700i

Page 1: ...play Fully Programmable 24 VAC with Worry Free Memory Storage English Spanish or French Display Option Two Year Warranty User s Manual 110 1023E DELUXE PROGRAMMABLE THERMOSTATS 110 1023E qxd 11 18 04...

Page 2: ...across terminals on the gas valve or at the system control to test installation This will damage the thermostat and void the warranty Do not connect ground to any terminal in this unit This thermostat...

Page 3: ...15 Detailed Information on the USER SETTINGS Or what do these USER SETTINGS do Page 16 When would I need to change the USER settings Page 18 What are the INSTALLER settings Page 19 When would I need...

Page 4: ...DOWN arrow to scroll through the days of the week hours or minutes Press SET to select desired value Press MAIN MENU when complete MONDAY 3 29 PM 78 1 HOLD TEMP MENU COOL FAN AUTO SET AT 78 OUTSIDE 24...

Page 5: ...d on all others are automatically shut off After pressing the SELECT button the main screen will automatically appear NOTE EMERGENCY HEAT is used only on the 9720i model AUTO CHANGEOVER appears only i...

Page 6: ...OFF cycle will start counting over again when the system shuts off 6 MONDAY 3 29 PM 78 1 HOLD TEMP MENU COOL FAN AUTO SET AT 78 OUTSIDE 24 F MENU DAY TIME HEAT COOL PROGRAM FAN HOME SELECT MORE MAIN...

Page 7: ...ichever is shorter For a longer duration see page 9 7 MONDAY 3 29 PM 78 1 HOLD TEMP MENU COOL FAN AUTO SET AT 78 OUTSIDE 24 F SET AT HOME SET TEMP 70 F UNTIL 6 30 PM MENU COOL FAN AUTO SET AT 70 F UNT...

Page 8: ...DOWN button to adjust the time Press SET TIME The main screen will now indicate a TEMPORARY HOLD until the desired time Press RESUME PROGRAM to return to the program operating mode MONDAY 3 29 PM 78...

Page 9: ...ogram Mode after being in HOLD Simply press the RESUME PROGRAM button This works from all HOLD screens 9 MONDAY 3 29 PM 78 1 HOLD TEMP MENU COOL FAN AUTO SET AT 78 OUTSIDE 24 F HOME SELECT HOLD SETTIN...

Page 10: ...d be blinking Use the UP or DOWN arrow to set the length of your vacation Press SET DAY The main screen will now indicate the VACATION settings Press RESUME PROGRAM to cancel and return to the program...

Page 11: ...ys to suit your lifestyle Please go to the next page for a continued discussion on How to program your thermostat 11 MONDAY 3 29 PM 78 1 HOLD TEMP MENU COOL FAN AUTO SET AT 78 OUTSIDE 24 F MORE MENU D...

Page 12: ...are programmed HEAT MONDAY PROGRAM MAIN MENU SET TIME COOL WAKE 06 00AM 70 78 MORN 08 30AM 62 85 EVE 04 30PM 70 78 NIGHT 10 30PM 62 82 HEAT MONDAY PROGRAM MAIN MENU SET HEAT COOL WAKE 06 30AM 70 78 MO...

Page 13: ...gram is to be copied Press FINISHED when complete After pressing FINISHED you can choose to pro gram other days or exit YES will take you back to the Select Program Days screen NO will exit you to the...

Page 14: ...Y is when everybody has left for school or work Event 3 EVE is the return period coming home from school or work Event 4 NIGHT is the night period when everybody is asleep Six events can be used espec...

Page 15: ...re can be as many as 12 USER SETTINGS in all as listed below For detailed information on each user setting please go to the next page 15 MONDAY 3 29 PM 78 1 HOLD TEMP MENU COOL FAN AUTO SET AT 78 OUTS...

Page 16: ...lays time in standard 12 hour format or military format SETPOINT TEMPERATURE Each event has a setpoint temperature Choose whether to display this value or not NUMBER OF EVENTS PER DAY Select events pe...

Page 17: ...thermostat AVG LOCAL REMOTE will take a temperature reading from both the thermostat and the remote sensor and average the two for even temperature control USE REMOTE SENSOR will disable the sensor in...

Page 18: ...e the first value press SELECT The second digit will be highlighted Repeat for all four values And don t forget your code If you do you will have to reset the entire thermostat and that will erase all...

Page 19: ...d 9701i 1st STAGE HEATING The 9701i and the 9715i can have a gas oil or electric first stage heating Choose the energy source for 1st stage heating 19 INSTALL MENU SELECT 1ST STAGE HEATING GAS OIL ELE...

Page 20: ...f BALANCE POINTS This screen will appear only when the optional outdoor sensor 9025i is connected to the thermostat When this sensor is used with the 9720i you can set the lower and upper temperatures...

Page 21: ...AUTO CHANGEOVER feature The deadband is the temperature difference from the setpoint temperature during which the heating or cooling will not be turned on This is adjustable from 2 8 F 1 0 4 C SECURIT...

Page 22: ...can be set for either HVAC system run time or based on the calendar If Run Time is chosen the service reminder will be set in hours After the HVAC system has been operating for the selected number of...

Page 23: ...an be used to improve the comfort of your home When used in conjunction with the local sensor on the thermostat the two sensors average the sensed temperature and control to that average temperature Y...

Page 24: ...permanently in memory So if your power is out for more than two hours simply reset the clock See page 4 How do I reset the thermostat program to factory conditions To reset the thermostat to factory c...

Page 25: ...F 29 C Evening 70 F 21 C 78 F 25 C Night 62 F 17 C 82 F 28 C Another way to contain costs is to cycle the heat pump or air conditioner with moderation The thermostat controls the cycle rate based on t...

Page 26: ...ter monitor If the WARNING screen is displayed the thermostat will shut down all operations including heating and cooling It s important to change the batteries promptly if this screen appears How do...

Page 27: ...warranty and our liability does not apply to merchandise that has been damaged caused by misuse neglect mishandling alterations improper installation or use in a way other than in accordance with the...