CRV-S
ERIES
I
NSTALLATION
, O
PERATION
AND
S
ERVICE
M
ANUAL
40 of 83
9.3 Horizontal Ventin
g
4" (10 cm) Pipe
FIGURE 19: EP-100 Horizontal Ventin
g
Confi
g
urations
25' (8 m) and 3 Elbows Maximum
50' (15 m) and 3 Elbows Maximum
Bird
Screen
4" (10 cm) Single Wall Pipe
5" (12.5 cm) Single Wall Pipe
Vent Terminal
Tjernlund VH1-4
Vent Terminal
Tjernlund VH1-6
Approved Thimbles
5" to 4" Reducer
(12.5 cm to 10 cm)
6" to 5" Reducer
(15 cm to 12.5 cm)
18" (46 cm) Minimum -
40" (102 cm) Maximum
18" (46 cm) Minimum -
40" (102 cm) Maximum
Pitch single wall pipe
downward away from pump
1/4" (6 mm) for every 10' (3 m).
4" (10 cm)
Band Clamp
Part Number
Description
Part Number
Description
01330203
Tee, 4" (10 cm) Aluminized
01327005
Condensate Neutralization Tube 2000
01331900
Damper Coupling, 4" (10 cm)
90502100
Vent Terminal, 4" (10 cm) (Combustible Wall)
01335801
Elbow, 4" (10 cm) Aluminized 90°
90502101
Vent Terminal, 6" (15 cm) (Combustible Wall)
01365400
Bird Screen, 4" (10 cm)
91409403
Tube, Aluminized 4" (10 cm) dia. 10' (3 m)
02537801-1P
Vent Terminal (Non-Combustible Wall)
91412800
Flexible Boot, 4" (10 cm)
02718851
Drain Cap, 4" (10 cm)
91901300
Boot Clamp, 4" (10 cm)
01327002
Condensate Neutralization Tube 200
Not Supplied
Tube, Aluminized 5" (12.7 cm) dia. 10' (3 m)
01327003
Condensate Neutralization Tube 600
Not Supplied
Tube Adapter, 5" (12.7 cm) dia. x 4" (10 cm) dia.
01327004
Condensate Neutralization Tube 1000
Not Supplied
Tube Adapter, 6" (15.2 cm) dia. x 5" (12.7 cm) dia.
Summary of Contents for CoRayVac CRV-B-10
Page 2: ......
Page 4: ......
Page 6: ......
Page 71: ...SECTION 13 STARTING THE SYSTEM 65 of 83 FIGURE 42 Vacuum Reading ...
Page 81: ...SECTION17 TROUBLESHOOTING 75 of 83 17 1 Troubleshooting Flow Chart ...
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......