Maximum of:
19 units (230V)
10 units (110V)
3.1.5
Safety cable
When hung or flown the fixture must be
secured by an additional hanging accessory
(such as a safety bond or cable) of suitable
length.
The combined weight of both the fixture and
the accessories must be considered when
choosing the load-bearing capability of safety
cable or bond.
Safety cables or bonds must be securely
attached to the back of the fixture and be as
short as possible, or rolled up as necessary,
to minimise travel distance should the fixture
be dislodged.
3.2
Electrical
3.2.1
LED source
Never touch or scratch LED surface.
See
5.1.5 LED cleaning procedure
if cleaning is necessary.
3.2.2
Power
Power supply
Voltage
Frequency
Input power
Connectors
90
264 V
47-63 Hz
0,8 A / 185 W @ 230V
1,5 A / 185 W @ 120V
1,8 A / 185 W @ 90V
Max.2,1 A
Mode veille: 7 W
Neutrik powerCON TRUE1
Entrée :
ref. NAC3PX (max. 20A)
Class 1 product.
This luminaire must be earthed.
Must be connected directly to AC power.
Do not connect to dimmer power
Automatic power detection
On the same breaker, maximum of: 19 units (230V) / 10 units (110V)
Daisy chain:
Power cable