0
Cur.
- A current temperature of the LEDs PCB.
Max.
- A maximum temperature of the LEDs PCB since the fixture has
been fabricated.
Max. Res.
- A maximum temperature of the LEDs PCB since the counter
was last reset.
In order to reset some counter to 0, touch desired text box under item "Max.Res."
Ambient Temperature
- The menu shows temperature on the PCB in the fixture arm (arm without tilt lock).
Current
- A current temperature on the PCB in the fixture arm.
Maximum NonRes.
- A maximum temperature on the PCB in the fixture arm since
the fixture has been fabricated.
Maximum Res.
- A maximum temperature on the PCB in the fixture arm since
since the counter was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
Base Temperature
- The menu shows temperature in the fixture base (on the display PCB).
Current
- A current temperature in the fixture base.
Maximum NonRes.
- A maximum temperature in the fixture base since the fixture has
been fabricated.
Maximum Res.
- A maximum temperature in the fixture base since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
DMX Values -
The menu is used to read DMX values of each channel received by the fixture.
Wireless State -
The menu serves for reading of the wireless operation status.
Unlink Wireless Adapter
- The item serves for unlinking the fixture from DMX transmitter.
Power Channel State -
The menu item shows state of the Power/Special functions switches.
Software Version
- Select this item to read the software version of the fixture modules:
Display System
- A display processor on the display board in the fixture base
Module M
- A pan/Tilt processors
Module DR
- A LEDs driver
Module DX
- zooms control
Module P1
- Prisms control
Module P2
- Prisms control
Module P3
- Prisms control
Product IDs -
The menu is used to read the MAC Address ,RDM UID and RDM Label.
View Logs
- Use this menu to read fixture´s data which have been recorded during fixture operation. This
colected data allows easier troubleshooting.
Fixture Errors
- Use this menu to read fixture errors which have occured during fixture operation.
Fixture States
- Recorded following actions: Fixture On, Fixture Off.
Fixture Position
- Recorded installation positions of the fixture:
Fixture Temperatures
- Recorded temperatures which have exceeded defined levels.
Note: The log buffer can contain 8000 records max. If the buffer is full, old data will be overwritten.